更新至 18.04 后未检测到外接显示器

更新至 18.04 后未检测到外接显示器

更新至 18.04 版后,我的外接显示器无法再被检测到。我尝试遵循以下建议:Ubuntu 18.04 上未检测到外接显示器(添加模式、安装 lightdm 等)但无济于事。输出xrandr如下:

Screen 0: minimum 320 x 200, current 1920 x 1080, maximum 8192 x 8192
eDP-1 connected primary 1920x1080+0+0 (normal left inverted right x axis y axis) 294mm x 165mm
   1920x1080     60.02*+  60.01    59.97    59.96    59.93    48.01  
   1680x1050     59.95    59.88  
   1600x1024     60.17  
   1400x1050     59.98  
   1600x900      59.99    59.94    59.95    59.82  
   1280x1024     60.02  
   1440x900      59.89  
   1400x900      59.96    59.88  
   1280x960      60.00  
   1440x810      60.00    59.97  
   1368x768      59.88    59.85  
   1360x768      59.80    59.96  
   1280x800      59.99    59.97    59.81    59.91  
   1152x864      60.00  
   1280x720      60.00    59.99    59.86    59.74  
   1024x768      60.04    60.00  
   960x720       60.00  
   928x696       60.05  
   896x672       60.01  
   1024x576      59.95    59.96    59.90    59.82  
   960x600       59.93    60.00  
   960x540       59.96    59.99    59.63    59.82  
   800x600       60.00    60.32    56.25  
   840x525       60.01    59.88  
   864x486       59.92    59.57  
   800x512       60.17  
   700x525       59.98  
   800x450       59.95    59.82  
   640x512       60.02  
   720x450       59.89  
   700x450       59.96    59.88  
   640x480       60.00    59.94  
   720x405       59.51    58.99  
   684x384       59.88    59.85  
   680x384       59.80    59.96  
   640x400       59.88    59.98  
   576x432       60.06  
   640x360       59.86    59.83    59.84    59.32  
   512x384       60.00  
   512x288       60.00    59.92  
   480x270       59.63    59.82  
   400x300       60.32    56.34  
   432x243       59.92    59.57  
   320x240       60.05  
   360x202       59.51    59.13  
   320x180       59.84    59.32  
DP-1 disconnected (normal left inverted right x axis y axis)
HDMI-1 disconnected (normal left inverted right x axis y axis)

显卡(运行sudo lshw -C video)的详细信息如下:

  *-display                 
       description: VGA compatible controller
       product: Intel Corporation
       vendor: Intel Corporation
       physical id: 2
       bus info: pci@0000:00:02.0
       version: 02
       width: 64 bits
       clock: 33MHz
       capabilities: pciexpress msi pm vga_controller bus_master cap_list rom
       configuration: driver=i915 latency=0
       resources: irq:131 memory:f0000000-f0ffffff memory:e0000000-efffffff ioport:e000(size=64) memory:c0000-dffff

有什么想法可以解决这个问题吗?我尝试使用相同的显示器和相同的电缆将同事笔记本电脑上的 Ubuntu 先前版本连接到一起,没有任何问题。

根据建议进行编辑:

使用实时图像部分解决了我的问题:我加载实时图像,重新启动计算机并提取它,现在它又出现了。奇怪的是,现在我登录时两个屏幕都被克隆了,但一旦我登录,显示器屏幕就会变黑。但是,如果我拔下并再次插入 HDMI 电缆,我就会得到我想要的配置(作为连接显示器,在显示器屏幕上有图标和栏)。