将热备盘添加到 Intel RST(板载 RAID)

将热备盘添加到 Intel RST(板载 RAID)

我正在使用 3 个磁盘 (RAID5),并且想要添加一个备用磁盘 (dev/sdd)。该系统使用Intel RST(板载RAID),可以被CentOS7和mdadm命令识别。但我尝试了很多方法,都无法将备用盘添加为“热备盘”。

[root@ehost ~]# mdadm --detail /dev/md/imsm0
/dev/md/imsm0:
      Version : imsm
   Raid Level : container
Total Devices : 3
Working Devices : 3
       UUID : 750b9700:31df2732:350d713c:10b17437
Member Arrays : /dev/md/Volume1
Number   Major   Minor   RaidDevice
   0       8        0        -        /dev/sda
   1       8       16        -        /dev/sdb
   2       8       32        -        /dev/sdc

[root@ehost ~]# mdadm --detail /dev/md126
/dev/md126:
  Container : /dev/md/imsm0, member 0
 Raid Level : raid5
 Array Size : 1953519616 (1863.02 GiB 2000.40 GB)
 Used Dev Size : 976759936 (931.51 GiB 1000.20 GB)
  Raid Devices : 3
 Total Devices : 3
         State : clean
Active Devices : 3
Working Devices : 3
Failed Devices : 0
 Spare Devices : 0

     Layout : left-asymmetric
 Chunk Size : 128K
       UUID : d984583f:721b097a:b725e6c2:55b874f4
Number   Major   Minor   RaidDevice State
   2       8        0        0      active sync   /dev/sda
   1       8       16        1      active sync   /dev/sdb
   0       8       32        2      active sync   /dev/sdc

[root@ehost ~]# mdadm --add /dev/md126 /dev/sdd
mdadm: Cannot add disks to a 'member' array, perform this operation on the parent container

[root@ehost ~]# mdadm --add /dev/md/imsm0 /dev/sdd
mdadm: added /dev/sdd

[root@ehost ~]# mdadm --detail /dev/md/imsm0
/dev/md/imsm0:
    Version : imsm
 Raid Level : container
 Total Devices : 4
Working Devices : 4
       UUID : 750b9700:31df2732:350d713c:10b17437
 Member Arrays : /dev/md/Volume1
Number   Major   Minor   RaidDevice

   0       8        0        -        /dev/sda
   1       8       16        -        /dev/sdb
   2       8       32        -        /dev/sdc
   3       8       48        -        /dev/sdd

[root@ehost ~]# mdadm --detail /dev/md126
/dev/md126:
  Container : /dev/md/imsm0, member 0
 Raid Level : raid5
 Array Size : 1953519616 (1863.02 GiB 2000.40 GB)
  Used Dev Size : 976759936 (931.51 GiB 1000.20 GB)
   Raid Devices : 3
     Total Devices : 3

      State : clean
 Active Devices : 3
Working Devices : 3
Failed Devices : 0
Spare Devices : 0
     Layout : left-asymmetric
 Chunk Size : 128K
       UUID : d984583f:721b097a:b725e6c2:55b874f4
Number   Major   Minor   RaidDevice State
   2       8        0        0      active sync   /dev/sda
   1       8       16        1      active sync   /dev/sdb
   0       8       32        2      active sync   /dev/sdc
[root@ehost ~]#

请帮忙帮忙,谢谢!埃德温

答案1

硬件 RAID 与软件 RAID 完全不同

在硬件 RAID 中,有一些硬件卡拥有磁盘。
该卡以不同的方式(作为 raid)向操作系统提供磁盘。

在软件 RAID 中,操作系统拥有设备(sda、sdb 等)并构建 raid 设备(在 Linux“多个设备”的情况下:md0、md1 等)

我怀疑您的 md126 是软件 raid,而 imsm0 是硬件 raid。

您是否使用过或激活过-e imsmmdadm的开关?

如果是这种情况,您需要使用英特尔软件来管理英特尔设备。

读这个

下载英特尔的 PDF

相关内容