我有一台服务器老是重启。上次我安装了 lm_sensors,发现它坏了,因为风扇不转,导致温度升高。
现在问题又出现了,lm_sensors 报告说风扇没有转,而且很多in1
东西in3
都不工作。
sysadmin@tesfaserver:~$ sensors
w83627dhg-isa-0290
Adapter: ISA adapter
Vcore: +1.30 V (min = +0.00 V, max = +1.74 V)
in1: +0.86 V (min = +0.76 V, max = +0.18 V) ALARM
AVCC: +3.39 V (min = +2.98 V, max = +3.63 V)
+3.3V: +3.39 V (min = +2.98 V, max = +3.63 V)
in4: +1.70 V (min = +1.38 V, max = +1.50 V) ALARM
in5: +1.74 V (min = +0.99 V, max = +1.65 V) ALARM
in6: +1.86 V (min = +1.95 V, max = +0.30 V) ALARM
3VSB: +3.49 V (min = +2.98 V, max = +3.63 V)
Vbat: +3.31 V (min = +2.70 V, max = +3.30 V) ALARM
fan1: 0 RPM (min = 1562 RPM, div = 32) ALARM
fan2: 0 RPM (min = 1687 RPM, div = 32) ALARM
fan3: 0 RPM (min = 727 RPM, div = 32) ALARM
fan4: 0 RPM (min = 878 RPM, div = 32) ALARM
fan5: 0 RPM (min = 811 RPM, div = 32) ALARM
temp1: +21.0°C (high = +90.0°C, hyst = +114.0°C) sensor = thermistor
temp2: +32.0°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor
temp3: +46.5°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor
cpu0_vid: +0.000 V
intrusion0: ALARM
sysadmin@tesfaserver:~$
有人能告诉我in1
和in2
等等是什么吗?他们发出警报会有什么后果?我该如何解决这个问题?
答案1
如果不知道您使用的 CPU 和主板、是否对 CPU 进行了超频等,就无法正确解释所显示的电压值。触发这些警报的 lm_sensors 默认值显然毫无意义,因此您可以忽略它们。
至于风扇,最可能的问题是它们根本没有插入。为了能够监控它们,风扇必须有一个 3 针或 4 针连接器,插入主板上的风扇连接器,并且您必须将风扇插入其中。
最后,在桌面主板上运行服务器(例如您正在做的)并不能保证其可靠性。