我正在几台 Windows 10 计算机上安装 Visual SourceSafe。我已经在几台机器上成功安装了,但其中几台计算机收到以下错误“加载安装组件时遇到问题。取消安装。”我已将日志附加到下面。如能得到任何帮助,我将不胜感激。
[05/24/19,13:34:11] Setup.exe:
[05/24/19,13:34:11] Setup.exe: ========== Logging started ==========
[05/24/19,13:34:11] Setup.exe: =====================================
[05/24/19,13:34:11] Setup.exe: GetGlobalCustomProperty({481CEF9F-033A-11D3-ACE2-00C04F8EEBA1})
[05/24/19,13:34:11] Setup.exe: GetGlobalCustomProperty(B51015E7-26A5-4c8f-B871-26ABA9BEFB65)
[05/24/19,13:34:11] Setup.exe: Command line parameters:
[05/24/19,13:34:11] Setup.exe: entering ISetupManager::RunIntro()
[05/24/19,13:34:11] Setup.exe: LoadSetupDatabase()
[05/24/19,13:34:11] Setup.exe: CSetupManager::LoadSetupDatabase() - set InstalledFrom property to \\sditapsn01\SDITAP89\Applications\Licensed Software\VisualSourceSafe2005
[05/24/19,13:34:11] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:11] Setup.exe: CSetupManager::LoadSuiteInfo() - we are in SP mode - no suiteinfo.dll is supported
[05/24/19,13:34:11] Setup.exe: Product Name:Microsoft Visual SourceSafe 2005 - English
[05/24/19,13:34:11] Setup.exe: ISetupManager::RunIntro() : LoadSuiteRequirements
[05/24/19,13:34:11] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:11] Setup.exe: ISetupManager::RunIntro() : CheckSuiteBlocks
[05/24/19,13:34:11] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:11] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:11] Setup.exe: ISetupManager::RunIntro() : LoadCommandLineMgr
[05/24/19,13:34:11] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:11] Setup.exe: ISetupManager::LoadCommandLineMgr() completed
[05/24/19,13:34:11] Setup.exe: ISetupManager::RunIntro() : LoadSetupLog
[05/24/19,13:34:11] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:11] Setup.exe: ISetupManager::LoadSetupLog() completed
[05/24/19,13:34:11] UTILS::RunNGENAction: Started
[05/24/19,13:34:11] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue pause"
[05/24/19,13:34:12] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:12] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue pause"
[05/24/19,13:34:12] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:12] Setup.exe: ISetupManager::RunIntro() : LoadManagers
[05/24/19,13:34:12] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:12] Setup.exe: inside ISetupManager::LoadUIManager()
[05/24/19,13:34:12] vs70uimgr: Entering InitializeModule() method.
[05/24/19,13:34:12] Setup.exe: CSetupManager::CopyTempFiles() - Installing setup files...
[05/24/19,13:34:12] Setup.exe: CSetupManager::InstallSetupFiles() starting
[05/24/19,13:34:12] Setup.exe: GetGlobalCustomProperty({39E467CB-8962-4AD8-99F9-864AFF183FD4})
[05/24/19,13:34:12] vs70uimgr: Entering ShowSmallProgress() method.
[05/24/19,13:34:13] Setup.exe: CSetupManager::CopyTempFiles() - Successfuly copied files to temp; rerunning Setup...
[05/24/19,13:34:14] Setup.exe: CSetupManager::CopyTempFiles() - Finished Rerunning Setup...
[05/24/19,13:34:14] Setup.exe: UnloadSuiteComponents()
[05/24/19,13:34:14] UTILS::RunNGENAction: Started
[05/24/19,13:34:14] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue continue"
[05/24/19,13:34:15] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:15] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue continue"
[05/24/19,13:34:15] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:15] Setup.exe: GetGlobalCustomProperty(AA4EEF91-FB37-4135-9B73-484B75DDAA42)
[05/24/19,13:34:25] Setup.exe:
[05/24/19,13:34:25] Setup.exe: ========== Logging started ==========
[05/24/19,13:34:25] Setup.exe: =====================================
[05/24/19,13:34:25] Setup.exe: GetGlobalCustomProperty({481CEF9F-033A-11D3-ACE2-00C04F8EEBA1})
[05/24/19,13:34:25] Setup.exe: GetGlobalCustomProperty(B51015E7-26A5-4c8f-B871-26ABA9BEFB65)
[05/24/19,13:34:25] Setup.exe: Command line parameters: /CreatedTemp /NoExclude /InstalledFrom "\\sditapsn01\SDITAP89\Applications\Licensed Software\VisualSourceSafe2005"
[05/24/19,13:34:25] Setup.exe: entering ISetupManager::RunIntro()
[05/24/19,13:34:25] Setup.exe: LoadSetupDatabase()
[05/24/19,13:34:25] Setup.exe: CSetupManager::LoadSetupDatabase() - set InstalledFrom property to C:\temp\SIT15659.tmp
[05/24/19,13:34:25] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:25] Setup.exe: CSetupManager::LoadSuiteInfo() - we are in SP mode - no suiteinfo.dll is supported
[05/24/19,13:34:25] Setup.exe: Product Name:Microsoft Visual SourceSafe 2005 - English
[05/24/19,13:34:25] Setup.exe: CSetupManager::RunIntro() - Initializing Progress Dialog Thread
[05/24/19,13:34:25] Setup.exe: CSetupManager::RunIntro() - Waiting for Initialization event...
[05/24/19,13:34:25] Setup.exe: CCoreEngine-Proc() - Setting loading init Event...
[05/24/19,13:34:25] Setup.exe: CCoreEngine-Proc() - Finished Setting loading init Event
[05/24/19,13:34:25] Setup.exe: CCoreEngine-Proc() - Entering Main Message Loop...
[05/24/19,13:34:25] Setup.exe: CSetupManager::RunIntro() - Initializing Progress Bar
[05/24/19,13:34:25] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:25] Setup.exe: ISetupManager::RunIntro() : LoadSuiteRequirements
[05/24/19,13:34:25] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:25] Setup.exe: ISetupManager::RunIntro() : CheckSuiteBlocks
[05/24/19,13:34:25] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:25] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:25] Setup.exe: ISetupManager::RunIntro() : LoadCommandLineMgr
[05/24/19,13:34:25] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:25] Setup.exe: ISetupManager::LoadCommandLineMgr() completed
[05/24/19,13:34:25] Setup.exe: ISetupManager::RunIntro() : LoadSetupLog
[05/24/19,13:34:25] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:25] Setup.exe: GetGlobalCustomProperty({1B3F6DC3-205F-11D3-A824-00C04FB1799F})
[05/24/19,13:34:25] Setup.exe: GetGlobalCustomProperty({383F0141-C682-4665-A69B-756E719C968D})
[05/24/19,13:34:25] Setup.exe: ISetupManager::LoadSetupLog() completed
[05/24/19,13:34:26] UTILS::RunNGENAction: Started
[05/24/19,13:34:26] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue pause"
[05/24/19,13:34:26] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:26] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue pause"
[05/24/19,13:34:27] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:27] Setup.exe: ISetupManager::RunIntro() : LoadManagers
[05/24/19,13:34:27] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:27] Setup.exe: inside ISetupManager::LoadDependencyMgr()
[05/24/19,13:34:27] Setup.exe: inside ISetupManager::LoadCDInfoMgr()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: inside ISetupManager::LoadDiskInfoMgr()
[05/24/19,13:34:27] Setup.exe: inside ISetupManager::LoadUIManager()
[05/24/19,13:34:27] vs70uimgr: Entering InitializeModule() method.
[05/24/19,13:34:27] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:27] Setup.exe: ISetupManager::RunIntro() : LoadDatabaseValues
[05/24/19,13:34:27] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:27] Setup.exe: GetCustomProperties()
[05/24/19,13:34:27] Setup.exe: get_CustomProperties()
[05/24/19,13:34:28] Setup.exe: GetGlobalCustomProperty({2C320A80-183E-4F7E-8832-66A0F5756221})
[05/24/19,13:34:28] Setup.exe: GetGlobalCustomProperty({8297A38B-6431-4F1D-9F6E-C3D371CEA383})
[05/24/19,13:34:28] Setup.exe: GetGlobalCustomProperty({B8A13F14-4BDE-4EC4-A53C-8E51FBB8261F})
[05/24/19,13:34:28] Setup.exe: GetGlobalCustomProperty({AA62DF98-3F2C-11D3-887B-00C04F8ECDD6})
[05/24/19,13:34:28] Setup.exe: GetCustomProperties()
[05/24/19,13:34:28] Setup.exe: get_CustomProperties()
[05/24/19,13:34:28] Setup.exe: GetGlobalCustomProperty({8297A38B-6431-4F1D-9F6E-C3D371CEA383})
[05/24/19,13:34:28] Setup.exe: GetGlobalCustomProperty({E0875D42-A33D-4C64-81C9-167795F29CA4})
[05/24/19,13:34:28] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:28] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:28] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:28] MSITOSIT: ***ERRORLOG EVENT*** : CRootComponent::SetManager() - MsiGetActiveDatabase returned an invalid handle
[05/24/19,13:34:28] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] MSITOSIT: ***ERRORLOG EVENT*** : ERROR processed; exception was thrown for retail build
Developer Comment: MsiGetActiveDatabase returned an invalid handle
Build Time: Thu Dec 11 15:04:18 2003
DWORD: 0
[05/24/19,13:34:29] Setup.exe: GetCustomProperties()
[05/24/19,13:34:29] Setup.exe: get_CustomProperties()
[05/24/19,13:34:29] Setup.exe: GetGlobalCustomProperty({8297A38B-6431-4F1D-9F6E-C3D371CEA383})
[05/24/19,13:34:29] Setup.exe: MoveLoadProgress()
[05/24/19,13:34:29] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] setup.exe: ***ERRORLOG EVENT*** : ISetupModule::SetManager() failed in ISetupManager::LoadSetupObjectGuid() : vs_setup.dll
[05/24/19,13:34:29] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::LoadSetupObjectname() - Failed in call to LoadSetupObjectGuid() for strName: in file: vs_setup.dll
[05/24/19,13:34:29] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] setup.exe: ***ERRORLOG EVENT*** : LoadComponent(), LoadSetupObjectName failure: vs_setup.dll
[05/24/19,13:34:29] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] setup.exe: ***ERRORLOG EVENT*** : LoadComponent failed in ISetupManager::LoadComponentsFromDBObject(): vs_setup.dll
[05/24/19,13:34:29] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::LoadDatabaseValues() - Failed in call to LoadComponentsFroMDBObjects()
[05/24/19,13:34:29] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:29] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::RunIntro() - Failed to Load Database Values
[05/24/19,13:34:29] vs70uimgr: Entering DisplayMessage() method.
[05/24/19,13:34:29] Setup.exe: CCoreEngine-Proc() - Finished Main Message Loop
[05/24/19,13:34:29] vs70uimgr: DisplayMessage_START:A problem has been encountered while loading the setup components. Canceling setup.
[05/24/19,13:34:31] vs70uimgr: DisplayMessage_END:A problem has been encountered while loading the setup components. Canceling setup.
[05/24/19,13:34:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,13:34:31] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::RunLoadSetup() - Failed to Run the Intro
[05/24/19,13:34:31] Setup.exe: UnloadSuiteComponents()
[05/24/19,13:34:31] UTILS::RunNGENAction: Started
[05/24/19,13:34:31] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue continue"
[05/24/19,13:34:32] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:32] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue continue"
[05/24/19,13:34:32] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,13:34:32] Setup.exe: GetGlobalCustomProperty(AA4EEF91-FB37-4135-9B73-484B75DDAA42)
[05/24/19,14:04:12] Setup.exe:
[05/24/19,14:04:12] Setup.exe: ========== Logging started ==========
[05/24/19,14:04:12] Setup.exe: =====================================
[05/24/19,14:04:12] Setup.exe: GetGlobalCustomProperty({481CEF9F-033A-11D3-ACE2-00C04F8EEBA1})
[05/24/19,14:04:12] Setup.exe: GetGlobalCustomProperty(B51015E7-26A5-4c8f-B871-26ABA9BEFB65)
[05/24/19,14:04:12] Setup.exe: Command line parameters:
[05/24/19,14:04:12] Setup.exe: entering ISetupManager::RunIntro()
[05/24/19,14:04:12] Setup.exe: LoadSetupDatabase()
[05/24/19,14:04:12] Setup.exe: CSetupManager::LoadSetupDatabase() - set InstalledFrom property to \\sditapsn01\SDITAP89\Applications\Licensed Software\VisualSourceSafe2005
[05/24/19,14:04:12] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:12] Setup.exe: CSetupManager::LoadSuiteInfo() - we are in SP mode - no suiteinfo.dll is supported
[05/24/19,14:04:12] Setup.exe: Product Name:Microsoft Visual SourceSafe 2005 - English
[05/24/19,14:04:13] Setup.exe: ISetupManager::RunIntro() : LoadSuiteRequirements
[05/24/19,14:04:13] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:13] Setup.exe: ISetupManager::RunIntro() : CheckSuiteBlocks
[05/24/19,14:04:13] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:13] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:13] Setup.exe: ISetupManager::RunIntro() : LoadCommandLineMgr
[05/24/19,14:04:13] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:13] Setup.exe: ISetupManager::LoadCommandLineMgr() completed
[05/24/19,14:04:13] Setup.exe: ISetupManager::RunIntro() : LoadSetupLog
[05/24/19,14:04:13] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:13] Setup.exe: ISetupManager::LoadSetupLog() completed
[05/24/19,14:04:13] UTILS::RunNGENAction: Started
[05/24/19,14:04:13] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue pause"
[05/24/19,14:04:13] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:04:13] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue pause"
[05/24/19,14:04:14] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:04:14] Setup.exe: ISetupManager::RunIntro() : LoadManagers
[05/24/19,14:04:14] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:14] Setup.exe: inside ISetupManager::LoadUIManager()
[05/24/19,14:04:14] vs70uimgr: Entering InitializeModule() method.
[05/24/19,14:04:14] Setup.exe: CSetupManager::CopyTempFiles() - Installing setup files...
[05/24/19,14:04:14] Setup.exe: CSetupManager::InstallSetupFiles() starting
[05/24/19,14:04:14] Setup.exe: GetGlobalCustomProperty({39E467CB-8962-4AD8-99F9-864AFF183FD4})
[05/24/19,14:04:14] vs70uimgr: Entering ShowSmallProgress() method.
[05/24/19,14:04:15] Setup.exe: CSetupManager::CopyTempFiles() - Successfuly copied files to temp; rerunning Setup...
[05/24/19,14:04:16] Setup.exe: CSetupManager::CopyTempFiles() - Finished Rerunning Setup...
[05/24/19,14:04:16] Setup.exe: UnloadSuiteComponents()
[05/24/19,14:04:16] UTILS::RunNGENAction: Started
[05/24/19,14:04:16] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue continue"
[05/24/19,14:04:17] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:04:17] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue continue"
[05/24/19,14:04:17] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:04:17] Setup.exe: GetGlobalCustomProperty(AA4EEF91-FB37-4135-9B73-484B75DDAA42)
[05/24/19,14:04:27] Setup.exe:
[05/24/19,14:04:27] Setup.exe: ========== Logging started ==========
[05/24/19,14:04:27] Setup.exe: =====================================
[05/24/19,14:04:27] Setup.exe: GetGlobalCustomProperty({481CEF9F-033A-11D3-ACE2-00C04F8EEBA1})
[05/24/19,14:04:27] Setup.exe: GetGlobalCustomProperty(B51015E7-26A5-4c8f-B871-26ABA9BEFB65)
[05/24/19,14:04:27] Setup.exe: Command line parameters: /CreatedTemp /NoExclude /InstalledFrom "\\sditapsn01\SDITAP89\Applications\Licensed Software\VisualSourceSafe2005"
[05/24/19,14:04:27] Setup.exe: entering ISetupManager::RunIntro()
[05/24/19,14:04:27] Setup.exe: LoadSetupDatabase()
[05/24/19,14:04:27] Setup.exe: CSetupManager::LoadSetupDatabase() - set InstalledFrom property to C:\temp\SIT21544.tmp
[05/24/19,14:04:27] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:27] Setup.exe: CSetupManager::LoadSuiteInfo() - we are in SP mode - no suiteinfo.dll is supported
[05/24/19,14:04:27] Setup.exe: Product Name:Microsoft Visual SourceSafe 2005 - English
[05/24/19,14:04:27] Setup.exe: CSetupManager::RunIntro() - Initializing Progress Dialog Thread
[05/24/19,14:04:27] Setup.exe: CSetupManager::RunIntro() - Waiting for Initialization event...
[05/24/19,14:04:27] Setup.exe: CCoreEngine-Proc() - Setting loading init Event...
[05/24/19,14:04:27] Setup.exe: CSetupManager::RunIntro() - Finished Waiting for Initialization event
[05/24/19,14:04:27] Setup.exe: CCoreEngine-Proc() - Entering Main Message Loop...
[05/24/19,14:04:27] Setup.exe: CSetupManager::RunIntro() - Initializing Progress Bar
[05/24/19,14:04:27] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:27] Setup.exe: ISetupManager::RunIntro() : LoadSuiteRequirements
[05/24/19,14:04:27] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:27] Setup.exe: ISetupManager::RunIntro() : CheckSuiteBlocks
[05/24/19,14:04:27] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:28] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:28] Setup.exe: ISetupManager::RunIntro() : LoadCommandLineMgr
[05/24/19,14:04:28] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:28] Setup.exe: ISetupManager::LoadCommandLineMgr() completed
[05/24/19,14:04:28] Setup.exe: ISetupManager::RunIntro() : LoadSetupLog
[05/24/19,14:04:28] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:28] Setup.exe: GetGlobalCustomProperty({1B3F6DC3-205F-11D3-A824-00C04FB1799F})
[05/24/19,14:04:28] Setup.exe: GetGlobalCustomProperty({383F0141-C682-4665-A69B-756E719C968D})
[05/24/19,14:04:28] Setup.exe: ISetupManager::LoadSetupLog() completed
[05/24/19,14:04:28] UTILS::RunNGENAction: Started
[05/24/19,14:04:28] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue pause"
[05/24/19,14:04:28] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:04:28] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue pause"
[05/24/19,14:04:29] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:04:29] Setup.exe: ISetupManager::RunIntro() : LoadManagers
[05/24/19,14:04:29] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:29] Setup.exe: inside ISetupManager::LoadDependencyMgr()
[05/24/19,14:04:29] Setup.exe: inside ISetupManager::LoadCDInfoMgr()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: inside ISetupManager::LoadDiskInfoMgr()
[05/24/19,14:04:29] Setup.exe: inside ISetupManager::LoadUIManager()
[05/24/19,14:04:29] vs70uimgr: Entering InitializeModule() method.
[05/24/19,14:04:29] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:29] Setup.exe: ISetupManager::RunIntro() : LoadDatabaseValues
[05/24/19,14:04:29] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:29] Setup.exe: GetCustomProperties()
[05/24/19,14:04:29] Setup.exe: get_CustomProperties()
[05/24/19,14:04:30] Setup.exe: GetGlobalCustomProperty({2C320A80-183E-4F7E-8832-66A0F5756221})
[05/24/19,14:04:30] Setup.exe: GetGlobalCustomProperty({8297A38B-6431-4F1D-9F6E-C3D371CEA383})
[05/24/19,14:04:30] Setup.exe: GetGlobalCustomProperty({B8A13F14-4BDE-4EC4-A53C-8E51FBB8261F})
[05/24/19,14:04:30] Setup.exe: GetGlobalCustomProperty({AA62DF98-3F2C-11D3-887B-00C04F8ECDD6})
[05/24/19,14:04:30] Setup.exe: GetCustomProperties()
[05/24/19,14:04:30] Setup.exe: get_CustomProperties()
[05/24/19,14:04:30] Setup.exe: GetGlobalCustomProperty({8297A38B-6431-4F1D-9F6E-C3D371CEA383})
[05/24/19,14:04:30] Setup.exe: GetGlobalCustomProperty({E0875D42-A33D-4C64-81C9-167795F29CA4})
[05/24/19,14:04:30] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:30] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:30] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:30] MSITOSIT: ***ERRORLOG EVENT*** : CRootComponent::SetManager() - MsiGetActiveDatabase returned an invalid handle
[05/24/19,14:04:30] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] MSITOSIT: ***ERRORLOG EVENT*** : ERROR processed; exception was thrown for retail build
Developer Comment: MsiGetActiveDatabase returned an invalid handle
Build Time: Thu Dec 11 15:04:18 2003
DWORD: 0
[05/24/19,14:04:31] Setup.exe: GetCustomProperties()
[05/24/19,14:04:31] Setup.exe: get_CustomProperties()
[05/24/19,14:04:31] Setup.exe: GetGlobalCustomProperty({8297A38B-6431-4F1D-9F6E-C3D371CEA383})
[05/24/19,14:04:31] Setup.exe: MoveLoadProgress()
[05/24/19,14:04:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] setup.exe: ***ERRORLOG EVENT*** : ISetupModule::SetManager() failed in ISetupManager::LoadSetupObjectGuid() : vs_setup.dll
[05/24/19,14:04:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::LoadSetupObjectname() - Failed in call to LoadSetupObjectGuid() for strName: in file: vs_setup.dll
[05/24/19,14:04:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] setup.exe: ***ERRORLOG EVENT*** : LoadComponent(), LoadSetupObjectName failure: vs_setup.dll
[05/24/19,14:04:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] setup.exe: ***ERRORLOG EVENT*** : LoadComponent failed in ISetupManager::LoadComponentsFromDBObject(): vs_setup.dll
[05/24/19,14:04:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::LoadDatabaseValues() - Failed in call to LoadComponentsFroMDBObjects()
[05/24/19,14:04:31] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:04:31] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::RunIntro() - Failed to Load Database Values
[05/24/19,14:04:31] vs70uimgr: Entering DisplayMessage() method.
[05/24/19,14:04:31] vs70uimgr: DisplayMessage_START:A problem has been encountered while loading the setup components. Canceling setup.
[05/24/19,14:04:31] Setup.exe: CCoreEngine-Proc() - Finished Main Message Loop
[05/24/19,14:25:35] vs70uimgr: DisplayMessage_END:A problem has been encountered while loading the setup components. Canceling setup.
[05/24/19,14:25:35] Setup.exe: AddGlobalCustomProperty
[05/24/19,14:25:35] setup.exe: ***ERRORLOG EVENT*** : CSetupManager::RunLoadSetup() - Failed to Run the Intro
[05/24/19,14:25:35] Setup.exe: UnloadSuiteComponents()
[05/24/19,14:25:35] UTILS::RunNGENAction: Started
[05/24/19,14:25:35] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework\v2.0.50727\ngen.exe queue continue"
[05/24/19,14:25:36] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:25:36] UTILS::RunNGENAction: starting "C:\WINDOWS\Microsoft.NET\Framework64\v2.0.50727\ngen.exe queue continue"
[05/24/19,14:25:36] UTILS::RunNGENAction: ngen.exe returned 0
[05/24/19,14:25:36] Setup.exe: GetGlobalCustomProperty(AA4EEF91-FB37-4135-9B73-484B75DDAA42)
[05/24/19,13:34:28] MSITOSIT: [2] CRootComponent::SetManager() - MsiGetActiveDatabase returned an invalid handle
[05/24/19,13:34:29] MSITOSIT: [2] ERROR processed; exception was thrown for retail build
Developer Comment: MsiGetActiveDatabase returned an invalid handle
Build Time: Thu Dec 11 15:04:18 2003
DWORD: 0
[05/24/19,13:34:29] setup.exe: [2] ISetupModule::SetManager() failed in ISetupManager::LoadSetupObjectGuid() : vs_setup.dll
[05/24/19,13:34:29] setup.exe: [2] CSetupManager::LoadSetupObjectname() - Failed in call to LoadSetupObjectGuid() for strName: in file: vs_setup.dll
[05/24/19,13:34:29] setup.exe: [0] LoadComponent(), LoadSetupObjectName failure: vs_setup.dll
[05/24/19,13:34:29] setup.exe: [0] LoadComponent failed in ISetupManager::LoadComponentsFromDBObject(): vs_setup.dll
[05/24/19,13:34:29] setup.exe: [2] CSetupManager::LoadDatabaseValues() - Failed in call to LoadComponentsFroMDBObjects()
[05/24/19,13:34:29] setup.exe: [2] CSetupManager::RunIntro() - Failed to Load Database Values
[05/24/19,13:34:31] setup.exe: [2] CSetupManager::RunLoadSetup() - Failed to Run the Intro
[05/24/19,14:04:30] MSITOSIT: [2] CRootComponent::SetManager() - MsiGetActiveDatabase returned an invalid handle
[05/24/19,14:04:30] MSITOSIT: [2] ERROR processed; exception was thrown for retail build
Developer Comment: MsiGetActiveDatabase returned an invalid handle
Build Time: Thu Dec 11 15:04:18 2003
DWORD: 0
[05/24/19,14:04:31] setup.exe: [2] ISetupModule::SetManager() failed in ISetupManager::LoadSetupObjectGuid() : vs_setup.dll
[05/24/19,14:04:31] setup.exe: [2] CSetupManager::LoadSetupObjectname() - Failed in call to LoadSetupObjectGuid() for strName: in file: vs_setup.dll
[05/24/19,14:04:31] setup.exe: [0] LoadComponent(), LoadSetupObjectName failure: vs_setup.dll
[05/24/19,14:04:31] setup.exe: [0] LoadComponent failed in ISetupManager::LoadComponentsFromDBObject(): vs_setup.dll
[05/24/19,14:04:31] setup.exe: [2] CSetupManager::LoadDatabaseValues() - Failed in call to LoadComponentsFroMDBObjects()
[05/24/19,14:04:31] setup.exe: [2] CSetupManager::RunIntro() - Failed to Load Database Values
[05/24/19,14:25:35] setup.exe: [2] CSetupManager::RunLoadSetup() - Failed to Run the Intro
答案1
该产品自 2005 年以来一直未使用,从一开始就不太好。此特定错误是 VisualStudio 2005 安装程序的一个已知错误(这是其中的一部分)。
我会建议使用任何事物除了 VSS 之外,微软以前甚至不会使用它...但我不是来评判的...只是帮助你。
为了解决这个问题,请尝试以下方法:
解决方案:将 TEMP 和 TMP 的 USER 变量更改为指向有效目录,例如 C:\TEMP。C:\TEMP 必须存在,并且所有用户都可以读取/写入。
你应该可以打开命令提示符(以管理员身份)并在其中设置 TEMP 和 TMP 变量。之后,确定使用相同的 cmd.exe 实例来启动安装程序。
如果 MSI 安装程序以某种方式直接读取用户环境变量,则您可能需要在 Windows 中临时设置用户环境变量(但我对此表示怀疑)。