我有一块金士顿 KC3000 2TB SSD。型号是 skc3000d2048g。
这个硬盘用了两年都没问题。金士顿软件说这个硬盘没问题。
但是,在系统重新启动之前,驱动器经常会表现得好像所有文件都丢失或损坏了一样。驱动器仍显示在文件资源管理器中(作为 D:),我可以浏览文件夹和文件。但是,如果我尝试从文件资源管理器打开文件,则会出现一个错误对话框,提示“指定了不存在的设备”。
这可能是什么原因造成的?我该怎么做才能解决问题?
以下是来自 CrystalDiskInfo 的 SMART 信息:
-- S.M.A.R.T. --------------------------------------------------------------
ID RawValues(6) Attribute Name
01 000000000000 Critical Warning
02 000000000133 Composite Temperature
03 000000000064 Available Spare
04 00000000000A Available Spare Threshold
05 000000000002 Percentage Used
06 0000014412BF Data Units Read
07 0000050745E7 Data Units Written
08 000006F13A71 Host Read Commands
09 00004875F533 Host Write Commands
0A 000000000BBF Controller Busy Time
0B 000000000052 Power Cycles
0C 00000000372E Power On Hours
0D 00000000000E Unsafe Shutdowns
0E 000000000000 Media and Data Integrity Errors
0F 0000000001BC Number of Error Information Log Entries
以下是金士顿 SSD 管理器的 SMART 信息:
[SMART Data]
######## Dump Smart Data ########,,,
ID(HEX), Description, Raw Value,Unit
0, Critical Warning,0x0000000000000000,-,
1, Composite Temperature,0x0000000000000142,K,
2, Available Spare,0x0000000000000064,%,
3, Available Spare Threshold,0x000000000000000a,%,
4, Percentage Used,0x0000000000000002,%,
5, Data Units Read,0x00000000014495a3,1000 unit,
6, Data Units Written,0x00000000050a194d,1000 unit,
7, Host Read Commands,0x0000000006f48c03,Count,
8, Host Write Commands,0x00000000489ea64c,Count,
9, Controller Busy Time,0x0000000000000bca,Mins,
0A, Power Cycles,0x0000000000000052,Count,
0B, Power On Hours,0x0000000000003755,Count,
0C, Unsafe Shutdowns,0x000000000000000e,Count,
0D, Media and Data Integrity Errors,0x0000000000000000,Count,
0E, Number of Error Info Log Entries,0x00000000000001bc,Count,
0F, Warning Composite Temperature Time,0x0000000000000000,Mins,
10, Critical Composite Temperature Time,0x0000000000000000,Mins,
11, Temperature Sensor 1,0x0000000000000000,K,
12, Temperature Sensor 2,0x0000000000000159,K,
13, Temperature Sensor 3,0x0000000000000000,K,
14, Temperature Sensor 4,0x0000000000000000,K,
15, Temperature Sensor 5,0x0000000000000000,K,
16, Temperature Sensor 6,0x0000000000000000,K,
17, Temperature Sensor 7,0x0000000000000000,K,
18, Temperature Sensor 8,0x0000000000000000,K,
19, Thermal Management Temperature 1 Transition Count,0x0000000000000000,NA,
1A, Thermal Management Temperature 2 Transition Count,0x0000000000000000,NA,
1B, Total Time For Thermal Management Temperature 1,0x000000000000002d,NA,
1C, Total Time For Thermal Management Temperature 2,0x0000000000000000,NA,
答案1
Kingston SSD SMART 属性与CrystalDiskInfo 的相同。
无论如何,参数没有显示任何错误。这可能是因为:(1)没有错误,或(2)固件状况不佳,不再更新这些统计数据。
选项 (1) 似乎与观察结果不符,因此您可以谨慎行事并淘汰此 SSD。磁盘在没有明显原因的情况下开始表现异常,这对您的数据来说是不安全的。
对于质量好的磁盘来说,两年的使用寿命很短。但是,从数据中我可以看到,磁盘在这段时间内几乎一直处于 24 小时/7 的通电状态,这可能会导致过早老化(尽管这不应该成为问题)。任何磁盘的质量主要取决于运气。