长时间显示“奇偶校验初始化状态:正在进行中”

长时间显示“奇偶校验初始化状态:正在进行中”

两周前,我在带有“Smart Array P400”(RAM 固件修订版 2.08,ROM 固件修订版 2.08)的“HP DL 380 G5”中安装了 6 个新硬盘(HP 500GB 6G 7.2K SFF 2.5 英寸 2 端口 SAS DualPort Midline,507610-B21)。

我创建了一个由 5 个物理磁盘(RAID 5)和一个备用驱动器(阵列 B)组成的新逻辑磁盘:

[...] => ctrl 全部显示配置

插槽 1 中的智能阵列 P400(sn:P61620D9SUKHBP)

阵列 A(SAS,未使用空间:0 MB)

  logicaldrive 1 (136.7 GB, RAID 1, OK)

  physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 146 GB, OK)
  physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 146 GB, OK)

阵列 B(SAS,未使用空间:0 MB)

  logicaldrive 2 (1.8 TB, RAID 5, OK)

  physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 500 GB, OK)
  physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 500 GB, OK)
  physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 500 GB, OK)
  physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 500 GB, OK)
  physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 500 GB, OK)
  physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 500 GB, OK, spare)

[...]

After that I could create the filesystem on It, mount It and use It without any issue.

My problem is that One week later the controller still was initializing parity.

[...] 阵列:B 接口类型:SAS 未使用空间:0 MB 状态:正常

  Logical Drive: 2
     Size: 1.8 TB
     Fault Tolerance: RAID 5
     Heads: 255
     Sectors Per Track: 32
     Cylinders: 65535
     Stripe Size: 64 KB
     Status: OK
     Array Accelerator: Enabled
     Parity Initialization Status: In Progress
     Unique Identifier: 600508B10010443953554B484250000C
     Disk Name: /dev/cciss/c0d1
     Mount Points: /buzonesdir 1.8 TB
     OS Status: LOCKED
     Logical Drive Label: A0C36F2EP61620D9SUKHBPA42A

[...]

At that moment, trying to speed up the parity initialization, I increased the rebuild and expand priority from "medium" to "high".

But, one week later (working with high priority) the "Parity Initialization Status" is still "In Progress".

Do you know if this is normal and I should let It continue working?
Do you know any way to check if really "Parity initialization" is being done and how long It will last?

Thank you very much.

答案1

重建/扩展优先级设置不会影响奇偶校验初始化。

请注意,奇偶校验初始化仅在控制器不忙时发生。如果您正在积极使用控制器,则初始化不会取得很大进展。为了尽快完成初始化,请让系统处于空闲状态,直到初始化完成。

您也可以通过将“表面扫描分析优先级”更改为“高”来获得一些成功。如果此设置设置为“延迟”,则控制器必须空闲指定的秒数,然后才能恢复表面扫描或奇偶校验初始化操作。将其设置为“高”应强制控制器进行一些即使它很忙,也会出现某种进展。不过,初始化完成后,您可能希望将其重置回其初始值。

答案2

先固件!

您的控制器比较旧,但自您运行的版本以来,控制器固件已发生了很多变化。您使用的是 ROM 修订版 2.08。Smart Array P400/P400i 为版本 7.22. 另请参阅HP 咨询表示相同。

浏览更改日志对于控制器,更新中解决了许多问题/错误。

你可以逐步安装固件,或者直接运行当前版本HP 固件 DVD使整个系统(包括磁盘)保持最新。

其他说明...

另请参阅:HP Smart Array P411 控制器上的 RAID-5 阵列奇偶校验初始化缓慢

答案3

磁盘固件更新可用。它可能会解决您的问题“此固件可防止在 WRITE SAME 命令序列期间可能发生的罕见情况,该情况可能会导致将不正确的数据写入硬盘驱动器。在 RAID ARRAY 奇偶校验初始化期间可能会使用 WRITE SAME 命令。”

相关内容