如何检查 HP P2000 上的 CPU 温度?

如何检查 HP P2000 上的 CPU 温度?

我有一个HP StorageWorks MSA 存储 P2000 G3 SAS大批。

show sensor-status给出了类似

# show sensor-status
Sensor Name                       Value    Status   
----------------------------------------------------
On-Board Temperature 1-Ctlr A     53 C     OK       
On-Board Temperature 1-Ctlr B     52 C     OK       
On-Board Temperature 2-Ctlr A     61 C     OK       
On-Board Temperature 2-Ctlr B     63 C     OK       
On-Board Temperature 3-Ctlr A     53 C     OK       
On-Board Temperature 3-Ctlr B     53 C     OK       
Disk Controller Temp-Ctlr A       34 C     OK       
Disk Controller Temp-Ctlr B       32 C     OK       
Memory Controller Temp-Ctlr A     66 C     OK       
Memory Controller Temp-Ctlr B     67 C     OK       
[...]
Overall Unit Status               OK       OK       
Temperature Loc: upper-IOM A      40 C     OK       
Temperature Loc: lower-IOM B      38 C     OK       
Temperature Loc: left-PSU         36 C     OK       
Temperature Loc: right-PSU        40 C     OK       
[...]

其中一个值是 CPU/FPGA 温度吗?如果不是,我该如何获取它?

谢谢!

答案1

这是一个奇怪的请求。为什么您要关心此 SAN 的一个组件的 CPU 温度,而不是整个系统和环境温度?

(编辑)看来你的冷却有问题。温度有点高!

不管怎样,这是我的 HP P2000 G3 SAS 存储单元的输出...前四个值代表 CPU 和FPGA系统中两个控制器的单元数。您还可以通过 SNMP 根据控制器 IP 地址提取此信息:

# show sensor-status
Sensor Name                       Value    Status   
----------------------------------------------------
CPU Temperature-Ctlr A            41       OK       
CPU Temperature-Ctlr B            41       OK       
FPGA Temperature-Ctlr A           42       OK       
FPGA Temperature-Ctlr B           44       OK       
Onboard Temperature 1-Ctlr A      27       OK       
Onboard Temperature 1-Ctlr B      27       OK       
Onboard Temperature 2-Ctlr A      35       OK       
Onboard Temperature 2-Ctlr B      36       OK       
Capacitor Temperature-Ctlr A      23       OK       
Capacitor Temperature-Ctlr B      23       OK       
Capacitor Pack Voltage-Ctlr A     8.22     OK       
Capacitor Pack Voltage-Ctlr B     8.12     OK       
Capacitor Cell 1 Voltage-Ctlr A   2.06     OK       
Capacitor Cell 1 Voltage-Ctlr B   2.02     OK       
Capacitor Cell 2 Voltage-Ctlr A   2.04     OK       
Capacitor Cell 2 Voltage-Ctlr B   2.02     OK       
Capacitor Cell 3 Voltage-Ctlr A   2.05     OK       
Capacitor Cell 3 Voltage-Ctlr B   2.03     OK       
Capacitor Cell 4 Voltage-Ctlr A   2.08     OK       
Capacitor Cell 4 Voltage-Ctlr B   2.05     OK       
Capacitor Charge-Ctlr A           99%      OK       
Capacitor Charge-Ctlr B           99%      OK       
Overall Unit Status               OK       OK       
Temperature Loc:upper-IOM A       34       OK       
Temperature Loc:lower-IOM B       33       OK       
Temperature Loc:left-PSU 1        29       OK       
Temperature Loc:right-PSU 2       26       OK       
Voltage 12V Loc:upper-IOM         11.86    OK       
Voltage 5V Loc:upper-IOM          5.05     OK       
Voltage 12V Loc:lower-IOM         11.86    OK       
Voltage 5V Loc:lower-IOM          5.05     OK       
Voltage 12V Loc:left-PSU 1        12.04    OK       
Voltage 5V Loc:left-PSU 1         5.12     OK       
Voltage 3.3V Loc:left-PSU 1       3.67     OK       
Voltage 12V Loc:right-PSU 2       12.04    OK       
Voltage 5V Loc:right-PSU 2        5.11     OK       
Voltage 3.3V Loc:right-PSU 2      3.68     OK       
Current 12V Loc:upper-IOM         4.20     OK       
Current 12V Loc:lower-IOM         4.24     OK       
Current 12V Loc:left-PSU 1        7.42     OK       
Current 5V Loc:left-PSU 1         5.57     OK       
Current 12V Loc:right-PSU 2       5.76     OK       
Current 5V Loc:right-PSU 2        4.78     OK       
----------------------------------------------------

答案2

P2000 不只是拥有一个可以完成所有工作的大型 CPU,它还拥有许多部件来提高设备的可靠性,您可以在此处看到这些部件的列表。您的盒子里有两个控制器(有些只有一个),每个控制器都有多个用于控制器的传感器,还有一个用于端口(磁盘)控制器和缓存(内存)控制器的传感器 - 因此您已经拥有了很多。

相关内容