无法在 Cisco 1760 上配置帧中继 T1

无法在 Cisco 1760 上配置帧中继 T1

我正在尝试通过帧中继配置数据 T1。

ISP 向我提供了以下信息:

1. IP address
2. Gateway address
3. Encapsulation Frame Relay
4. DLCI 100
5. BZ8 ESF (I think the bz8 was supposed to be b8zs)
6. Time Slot (1 al 24).

到目前为止我所配置的内容如下:

interface Serial0/0
  ip address <ip address> 255.255.255.252
  encapsulation frame-relay
  service-module t1 timeslots 1-24
  frame-relay interface-dlci 100

sh 服务模块 s0/0(输出):

Module type is T1/fractional
    Hardware revision is 0.128, Software revision is 0.2,
    Image checksum is 0x73D70058, Protocol revision is 0.1
Receiver has no alarms.
Framing is **ESF**, Line Code is **B8ZS**, Current clock source is line,
Fraction has **24 timeslots** (64 Kbits/sec each), Net bandwidth is 1536 Kbits/sec.
Last module self-test (done at startup): Passed
Last clearing of alarm counters 00:17:17
    loss of signal        :    0,
    loss of frame         :    0,
    AIS alarm             :    0,
    Remote alarm          :    2, last occurred 00:10:10
    Module access errors  :    0,
Total Data (last 1 15 minute intervals):
    0 Line Code Violations, 0 Path Code Violations
    0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
    0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in current interval (138 seconds elapsed):
    0 Line Code Violations, 0 Path Code Violations
    0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
    0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs

复制代码

FastEthernet0/0 is up, line protocol is up
  Hardware is PQUICC_FEC, address is 000d.6516.e5aa (bia 000d.6516.e5aa)
  Internet address is 10.0.0.1/24
  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex, 100Mb/s, 100BaseTX/FX
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:20:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters never
  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     0 packets input, 0 bytes
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 watchdog
     0 input packets with dribble condition detected
     191 packets output, 20676 bytes, 0 underruns
     0 output errors, 0 collisions, 1 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out

Serial0/0 is up, line protocol is down
  Hardware is PQUICC with Fractional T1 CSU/DSU
  MTU 1500 bytes, BW 1536 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY, loopback not set
  Keepalive set (10 sec)
  LMI enq sent  157, LMI stat recvd 0, LMI upd recvd 0, DTE LMI down
  LMI enq recvd 23, LMI stat sent  0, LMI upd sent  0
  LMI DLCI 1023  LMI type is CISCO  frame relay DTE
  FR SVC disabled, LAPF state down
  Broadcast queue 0/64, broadcasts sent/dropped 2/0, interface broadcasts 0
  Last input 00:24:51, output 00:00:05, output hang never
  Last clearing of "show interface" counters 00:27:20
  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: weighted fair
  Output queue: 0/1000/64/0 (size/max total/threshold/drops)
     Conversations  0/1/256 (active/max active/max total)
     Reserved Conversations 0/0 (allocated/max allocated)
     Available Bandwidth 1152 kilobits/sec
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     23 packets input, 302 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     1725 input errors, 595 CRC, 1099 frame, 0 overrun, 0 ignored, 30 abort
     246 packets output, 3974 bytes, 0 underruns
     0 output errors, 0 collisions, 48 interface resets
     0 output buffer failures, 0 output buffers swapped out
     4 carrier transitions
     DCD=up  DSR=up  DTR=up  RTS=up  CTS=up

Serial0/0.1 is down, line protocol is down
  Hardware is PQUICC with Fractional T1 CSU/DSU
  MTU 1500 bytes, BW 1536 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY
  Last clearing of "show interface" counters never
Serial0/0.100 is down, line protocol is down
  Hardware is PQUICC with Fractional T1 CSU/DSU
  Internet address is <ip address>/30
  MTU 1500 bytes, BW 1536 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY
  Last clearing of "show interface" counters never

对我来说一切似乎都已解释清楚,但显然我忽略了一些东西。

我的问题是我被困在接口启动、线路协议关闭的状态,所以 T1 无法启动。

答案1

你正在显示远程警报,你可能会发现思科故障排除指南有用。

假设硬件良好...

我会检查路由器和分界点之间的电缆,确保它已插入、未损坏、电缆没有损坏等。然后我会打电话给 ISP,询问他们为什么它不工作。上次我遇到这种情况是因为 AT&T 搞砸了,给了我错误的 DLCI,我花了六个小时的电话会议才弄清楚……


从您的更新中我了解到:

     1725 input errors, 595 CRC, 1099 frame, 0 overrun, 0 ignored, 30 abort

经验丰富的人可能会有更好的想法,但这绝对让我怀疑你的布线有问题,或者线路噪音太大,或者电信公司的时钟完全错误。可能是时候召开电话会议了。