VMware ESXi 5 性能缓慢,数百个 I/O 延迟错误。

VMware ESXi 5 性能缓慢,数百个 I/O 延迟错误。

我们有一个独立的 ESXi5 服务器,其硬件规格如下: - Supermicro X8DTL - Intel Xeon(R) CPU E5506 2.13GHz - 25G Ram - 1TB HD(镜像 RAID、本地 SATA)

我们大约有 17 台虚拟机在运行,每台约 512MB。运行 web+db 服务器。

大约一个月前我们的服务器崩溃了,经调查我们在 /scratch/log/vobd.log 中发现了类似这样的错误:

2013-02-21T23:30:14.054Z: [scsiCorrelator] 1657239493834us: [vob.scsi.device.io.latency.improved] Device mpx.vmhba2:C0:T0:L0 performance has improved. I/O latency reduced from 1310595 microseconds to 260642 microseconds.
2013-02-21T23:30:17.888Z: [scsiCorrelator] 1657243328201us: [vob.scsi.device.io.latency.improved] Device mpx.vmhba2:C0:T0:L0 performance has improved. I/O latency reduced from 260642 microseconds to 85292 microseconds.
2013-02-21T23:30:39.275Z: [scsiCorrelator] 1657264714482us: [vob.scsi.device.io.latency.high] Device mpx.vmhba2:C0:T0:L0 performance has deteriorated. I/O latency increased from average value of 43610 microseconds to 1310310 microseconds.
2013-02-21T23:30:39.275Z: [scsiCorrelator] 1657263440772us: [esx.problem.scsi.device.io.latency.high] Device mpx.vmhba2:C0:T0:L0 performance has deteriorated. I/O latency increased from average value of 43610 microseconds to 1310310 microseconds.
2013-02-21T23:30:42.796Z: [scsiCorrelator] 1657268235408us: [vob.scsi.device.io.latency.improved] Device mpx.vmhba2:C0:T0:L0 performance has improved. I/O latency reduced from 1310310 microseconds to 257850 microseconds.
2013-02-21T23:30:44.392Z: [scsiCorrelator] 1657269831493us: [vob.scsi.device.io.latency.improved] Device mpx.vmhba2:C0:T0:L0 performance has improved. I/O latency reduced from 257850 microseconds to 86289 microseconds.
2013-02-21T23:32:29.119Z: [scsiCorrelator] 1657374559512us: [vob.scsi.device.io.latency.high] Device mpx.vmhba2:C0:T0:L0 performance has deteriorated. I/O latency increased from average value of 43613 microseconds to 1405607 microseconds.
2013-02-21T23:32:29.120Z: [scsiCorrelator] 1657373285533us: [esx.problem.scsi.device.io.latency.high] Device mpx.vmhba2:C0:T0:L0 performance has deteriorated. I/O latency increased from average value of 43613 microseconds to 1405607 microseconds.
2013-02-21T23:32:35.673Z: [scsiCorrelator] 1657381113191us: [vob.scsi.device.io.latency.improved] Device mp

在崩溃当天,我们遇到了近 5000 个此类错误,从那时起,我们每天遇到的错误最少是 2 个,最多是 500 个(尽管没有整个服务器崩溃)。在客户虚拟机上,我们在正常使用过程中遇到了磁盘读写缓慢的问题。在 / 上使用 find 命令之类的简单操作都会导致性能图表出现大幅飙升。

我们已经更换了两个硬盘和 RAID 控制器。具有相同设置和类似数量 VM 的服务器没有这些问题。在第一次崩溃(有 5k 个错误)之前,性能很好,但是日志仍然显示相同的错误每天大约 30-40 次。在这次崩溃前几天,我们为客户 VM 精简配置了一个大硬盘(160GB)。

以下是(日期,错误信息弹出的次数,错误前记录的平均延迟(MS)和错误后的平均延迟(MS))

2012-10-24    16           976     138,666
2012-10-28    12         1,020      40,421
2012-11-05    16         1,167     273,223
2012-11-06    20         1,226      89,181
2012-11-07    40         1,314     224,957
2012-11-08    48         1,378     165,349
2012-11-09    42         1,441     174,061
2012-11-10    26         1,519     218,381
2012-11-11     8         1,567     112,229
2012-11-12    24         1,593     233,350
2012-11-13    54         1,641     193,695
2012-11-14    80         1,692     222,456
2012-11-15    32         1,738     243,640
2012-11-16    66         1,776     325,366
2012-11-17    30         1,816     176,468
2012-11-18    38         1,850     264,176
2012-11-20    12         1,846     117,589
2012-11-21    34         1,868     252,732
2012-11-22    44         1,895     166,636
2012-11-23    12         1,926     123,632
2012-11-26     4         1,892      98,791
2012-11-27    14         1,899     184,382
2012-11-28    20         1,916     178,908
2012-11-29    10         1,923     134,338
2012-11-30     6         1,923      69,203
2012-12-01     2         1,924      60,052
2012-12-02     4         1,919     122,631
2012-12-03     8         1,898     126,051
2012-12-04    54         1,909     199,758
2012-12-05   462         2,109     394,950
2012-12-06    36         2,228     191,166
2012-12-07    64         2,245     204,348
2012-12-08    32         2,271     294,890
2012-12-10   140         2,290     302,435
2012-12-11   314         2,386     311,973
2012-12-12   150         2,475     261,258
2012-12-13   160         2,532     236,761
2012-12-14   114         2,585     206,043
2012-12-15    84         2,618     211,221
2012-12-16    52         2,640     256,677
2012-12-17    18         2,637     180,975
2012-12-18    62         2,649     228,785
2012-12-19    92         2,669     199,357
2012-12-20   160         2,707     275,119
2012-12-21   124         2,749     245,460
2012-12-22     2         2,763     102,838
2012-12-26   144         2,736     302,383
2012-12-27   140         2,776     292,725
2012-12-28    64         2,813     274,609
2012-12-30   106         2,811     231,112
2012-12-31   148         2,853     295,416
2013-01-01    12         2,881     204,615
2013-01-04     4         2,860      90,300
2013-01-09   246         2,849     279,765
2013-01-10   278         2,909     301,014
2013-01-11   242         2,966     294,417
2013-01-12    92         3,006     308,232
2013-01-14   248         3,036     271,435
2013-01-15   426         3,172     233,094
2013-01-16   388         3,313     276,185
2013-01-17   342         3,423     282,632
2013-01-18   298         3,517     255,919
2013-01-19   232         3,579     287,905
2013-01-20     8         3,611     128,877
2013-01-21     2         3,614     121,942
2013-01-22   142         3,667     265,338
2013-01-23   402         3,738     281,091
2013-01-24   332         3,826     280,295
2013-01-25   178         3,892     270,747
2013-01-26   280         4,018     319,368
2013-01-27   106         4,075     293,760
2013-01-28   610         4,187     213,410
2013-01-29   784         4,700     222,077
2013-01-30   386         5,236     258,133
2013-01-31  4580         8,261   1,681,902
2013-02-01     2        11,211     339,135
2013-02-02    10        38,909   1,200,144
2013-02-04    18        88,573   2,692,687
2013-02-05   190        67,454   2,094,093
2013-02-06   460        58,534   1,858,435
2013-02-07    98        57,683   1,795,912
2013-02-08    62        54,012   1,671,730
2013-02-09    88        52,681   1,711,773
2013-02-10    66        51,016   1,549,408
2013-02-11    84        48,885   1,639,267
2013-02-12   206        48,364   1,829,969
2013-02-13   562        48,651   1,774,433
2013-02-14   170        48,957   1,655,395
2013-02-15   124        47,055   1,550,294
2013-02-16   140        46,099   1,588,326
2013-02-17   110        45,283   1,485,211
2013-02-18    34        43,836   1,356,562
2013-02-19   326        43,608   1,484,757
2013-02-20   224        43,894   1,581,129
2013-02-21   296        43,626   1,568,687

此刻我们几乎不知所措,我们能想到的最佳答案是,由于我们使用的是 SATA 驱动器(这可能是一个糟糕的想法),因此我们遇到了很大的瓶颈。我们计划迁移到带有 SAS 驱动器的 SAN,但我们想确保问题不会困扰我们。

谢谢

答案1

老实说,你可能已经解决了你自己的问题!

  • 您已经确定了问题的影响...以及可能的来源。
  • 你已经确认了在类似的设置上工作。
  • 您观察到单台机器上出现了不良行为。
  • 您没有更换底盘或背板。您的问题可能就出在那里。
  • 您购买了 Supermicro,但它并不具备 IBM、HP 或 Dell 产品那样的精致度或质量控制一致性。

发生这种情况。更换服务器并继续。

答案2

这不是一个真正的问题,但是...

您的 RAID 控制器可能已切换到直写模式。原因之一可能是 BBU 故障(或其学习周期)。这会大大降低性能。