硬盘因未知原因离线

硬盘因未知原因离线

我有 7 个系统运行以下设置。偶尔会有另一个磁盘脱机,但仔细检查后发现磁盘完好无损,至少还能再运行一年。由于这 7 个系统都发生过这种情况,因此我认为不太可能是某个部件(例如电缆)出了问题,而是一些略微不兼容的部件组合出了问题。

问题在于找出不兼容的确切位置。

(如果你有其他解决方法,比如通过命令行虚拟地重新安装硬盘,那么你也许可以回答https://serverfault.com/questions/523315/re-activate-device-that-is-considered-dead)。

服务器硬件:Dell 1950、Dell R815、Dell R715。

操作系统:

$ uname -a
Linux franklin 3.2.0-4-amd64 #1 SMP Debian 3.2.41-2+deb7u2 x86_64 GNU/Linux

控制器:

$ lspci |grep 22: 
22:00.0 Serial Attached SCSI controller: LSI Logic / Symbios Logic SAS2008 PCI-Express Fusion-MPT SAS-2 [Falcon] (rev 03)
$ sas2flash -listall
LSI Corporation SAS2 Flash Utility
Version 15.00.00.00 (2012.11.06) 
Copyright (c) 2008-2012 LSI Corporation. All rights reserved

    Adapter Selected is a LSI SAS: SAS2008(B2)   

Num   Ctlr            FW Ver        NVDATA        x86-BIOS         PCI Addr
----------------------------------------------------------------------------

1  SAS2008(B2)     15.00.00.00    0f.00.00.04    07.29.00.00     00:22:00:00

    Finished Processing Commands Successfully.
    Exiting SAS2Flash.

SAS/SATA 扩展器 Supermicro 4U SAS/SATA 扩展器背板,带有单个 LSI SAS2X36 扩展器芯片:

cat /sys/devices/pci0000:20/0000:20:03.0/0000:22:00.0/host5/port-5:0/expander-5:0/port-5:0:21/end_device-5:0:21/target5:0:21/5:0:21:0/model
SAS2X36         
cat /sys/devices/pci0000:20/0000:20:03.0/0000:22:00.0/host5/port-5:0/expander-5:0/port-5:0:21/end_device-5:0:21/target5:0:21/5:0:21:0/rev
0717

磁盘:

$ cat /sys/devices/pci0000:20/0000:20:03.0/0000:22:00.0/host5/port-5:0/expander-5:0/port-5:0:1/end_device-5:0:1/target5:0:1/5:0:1:0/model
Hitachi HDS72404
$ cat /sys/devices/pci0000:20/0000:20:03.0/0000:22:00.0/host5/port-5:0/expander-5:0/port-5:0:1/end_device-5:0:1/target5:0:1/5:0:1:0/rev
A3B0

一个系统中的磁盘:

$ cat /sys/devices/pci0000:20/0000:20:0b.0/0000:23:00.0/host5/port-5:0/expander-5:0/port-5:0:8/end_device-5:0:8/target5:0:8/5:0:8:0/model
ST3000DM001-9YN1
$ cat /sys/devices/pci0000:20/0000:20:0b.0/0000:23:00.0/host5/port-5:0/expander-5:0/port-5:0:8/end_device-5:0:8/target5:0:8/5:0:8:0/rev
CC4C

系统日志:

sd 5:0:22:0: [sdw] Unhandled error code
mpt2sas1: log_info(0x31120303): originator(PL), code(0x12), sub_code(0x0303)
sd 5:0:22:0: [sdw] Unhandled error code
mpt2sas1: log_info(0x31120303): originator(PL), code(0x12), sub_code(0x0303)
sd 5:0:22:0: [sdw]
mpt2sas1: log_info(0x31120303): originator(PL), code(0x12), sub_code(0x0303)
Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
sd 5:0:22:0: [sdw] CDB: Write(10): 2a 00 3a 92 b9 00 00 01 00 00
end_request: I/O error, dev sdw, sector 982694144
sd 5:0:22:0: [sdw]  Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
sd 5:0:22:0: [sdw] CDB: Write(10): 2a 00 3a 92 b7 00 00 01 00 00
end_request: I/O error, dev sdw, sector 982693632
sd 5:0:22:0: [sdw] Unhandled error code
sd 5:0:22:0: [sdw]  Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
sd 5:0:22:0: [sdw] CDB: Read(16):
sd 5:0:22:0: [sdw] Unhandled error code
 88 00 00 00 00 01 43 e2 f2 d0 00 00 00 10 00 00
end_request: I/O error, dev sdw, sector 5433914064
sd 5:0:22:0: [sdw]  Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
sd 5:0:22:0: [sdw] CDB: Write(10): 2a 00 3a 92 bd 00 00 01 00 00
end_request: I/O error, dev sdw, sector 982695168
sd 5:0:22:0: [sdw]  Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
md/raid:md4: Disk failure on sdw, disabling device.
md/raid:md4: Operation continuing on 9 devices.
scsi 5:0:22:0: [sdw] Unhandled error code
scsi 5:0:22:0: [sdw]  Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
scsi 5:0:22:0: [sdw] CDB: Write(10): 2a 00 3a 92 b8 00 00 01 00 00
end_request: I/O error, dev sdw, sector 982693888
scsi 5:0:22:0: [sdw] Unhandled error code
scsi 5:0:22:0: [sdw]  Result: hostbyte=DID_NO_CONNECT driverbyte=DRIVER_OK
scsi 5:0:22:0: [sdw] CDB: Write(10): 2a 00 3a 92 bc 00 00 01 00 00
end_request: I/O error, dev sdw, sector 982694912
mpt2sas1: removing handle(0x0021), sas_addr(0x500304800182694c)

答案1

我们这里缺少信息。您建议在此存储设置中每台服务器配备 24-45 个磁盘。

  • 您正在使用哪种特定控制器?
  • 由于磁盘数量较多,您可能将一些驱动器放在外部机箱中。请提供所用外部驱动器机箱的品牌/型号。
  • 您使用什么特定驱动器型号?全部磁盘是桌面级驱动器吗?
  • 您正在使用什么文件系统?
  • 描述磁盘和 RAID 布局。
  • 这是一直存在的问题吗?还是随着时间的推移逐渐形成的?
  • 超微是否参与了此设置的任何地方?

根据机箱设置,您可能会遇到 SATA 超时或总线错误。产生不良影响在连接到控制器的所有驱动器上。

另一个问题可能是 SAS/SATA 链路协商不佳。当 1.5Gbps 和 6.0Gbps 驱动器混合在同一块板上时,我在某些 SAS 扩展器上确实遇到过这种情况。

请提供更多信息。

相关内容