PowerEdge R720 磁盘性能缓慢

PowerEdge R720 磁盘性能缓慢

每隔几个月,配备 SSD(INTEL SSDSA2BW60)的 PowerEdge 就会产生如下结果:

hdparm -tT /dev/sda

/dev/sda:
 Timing cached reads:   690 MB in  2.00 seconds = 344.84 MB/sec
 Timing buffered disk reads: 170 MB in  3.00 seconds =  56.59 MB/sec
100000+0 records in
100000+0 records out
819200000 bytes (819 MB) copied, 66.0552 s, 12.4 MB/s

这些是在系统上关闭所有服务以避免干扰 hdparm。几个小时后,一切都恢复正常磁盘速度,行为无法重现。戴尔机器或英特尔 SSD 驱动器是否存在一些已知问题?

相关部分来自dmesg

Linux version 2.6.32-358.11.1.el6.x86_64 ([email protected]) (gcc version 4.4.7 20120313 (Red Hat 4.4.7-3) (GCC) ) #1 SMP Wed Jun 12 03:34:52 UTC 2013
DMI: Dell Inc. PowerEdge R720/0XH7F2, BIOS 1.6.0 03/07/2013
scsi0 : LSI SAS based MegaRAID driver
scsi 0:0:0:0: Direct-Access     DELL     PERC H710        3.13 PQ: 0 ANSI: 5
scsi 0:2:0:0: Direct-Access     DELL     PERC H710        3.13 PQ: 0 ANSI: 5
sd 0:2:0:0: [sda] 1170997248 512-byte logical blocks: (599 GB/558 GiB)
sd 0:2:0:0: [sda] Write Protect is off
sd 0:2:0:0: [sda] Mode Sense: 1f 00 00 08
sd 0:2:0:0: [sda] Write cache: enabled, read cache: enabled, doesn't support DPO or FUA
 sda: sda1 sda2 sda3
sd 0:2:0:0: [sda] Attached SCSI disk

答案1

您应该检查磁盘的 SMART 信息。您所描述的情况可能是由芯片故障引起的,然后由 SSD 的内部 RAID 结构替换,这个过程可能需要几个小时,并且会导致性能下降。如果性能下降确实在 SSD 内部,则无法真正知道性能下降的原因是什么,但您可能会注意到 SMART 重新分配计数器的前后发生了变化,表明确实发生了重新分配过程。

相关内容