HP 智能阵列 p800 电池电量不足

HP 智能阵列 p800 电池电量不足

当它在启用和禁用之间切换时,我们不断收到电子邮件通知。这是旧硬件,所以我们不会更换电池。

这是我们收到的警报。

Accelerator Board Status Change: Slot 5.
Status is now Temporarily Disabled.
Accelerator Board Status Change: Slot 5.
Status is now Enabled.

问题。我们可以在系统运行时禁用缓存吗?我需要更改 hpacucli 中的哪些选项?似乎有很多。

<target> modify [arrayaccelerator=enable|disable]
 Enables or disables the array accelerator for a given logical drive. The
 target can be any valid logical drive target on a controller that supports
 array accelerator management.
<target> modify [drivewritecache=enable|disable|?] [forced]
 Enables or disables the physical drive write cache for the controller. The
 target can be any valid controller target that supports drive write cache.
<target> modify [nobatterywritecache=enable|disable|?]
 This option allows write caching to be enabled when a battery/capacitor is
 not present or fully charged. This setting affects all logical drives
 created on the controller and there must be at least one logical drive
 present before usage.

答案1

如果您确实想要禁用此写入缓存,那么您需要第二个选项。

drivewritecache=disable

第一个选项只是阻止特定逻辑驱动器使用它。第三个选项将允许缓存运行,但您将失去电池备份,这本身就很危险。

答案2

购买新电池...购买二手电池...致电 HP...如果您打算继续运行那么旧的服务器,至少要做好它:)

是的你可以禁用电池要求对于写入缓存...如果你不担心在崩溃或断电期间丢失正在运行的写入,那就没问题。我更担心的是那些旧电池会开始膨胀。我见过这种情况,有点恶心(一个在 DL180 G5 机箱内爆炸)。

看:Smart Array P400 - 加速器更换电池故障