提到问题这里,我也试图获取所有属性,正如本博客中解释的那样这里。
我使用 Debian 6 作为操作系统,并使用 apt-get 安装了 smartmontools 版本 6.3。我的 6 个磁盘位于 RAID 上。我首先使用以下命令启用了统计信息
sudo smartctl -s on -o on -S on -d megaraid,0 /dev/sda
sudo smartctl -s on -o on -S on -d megaraid,1 /dev/sda
sudo smartctl -s on -o on -S on -d megaraid,2 /dev/sda
sudo smartctl -s on -o on -S on -d megaraid,3 /dev/sda
sudo smartctl -s on -o on -S on -d megaraid,4 /dev/sda
sudo smartctl -s on -o on -S on -d megaraid,5 /dev/sda
完成后,我将使用以下命令获取所有属性:
smartctl -a -i -d megaraid,0 /dev/sda
但我没有看到博客文章中所说的任何属性。
bash-4.1# smartctl -a -i -d megaraid,0 /dev/sda
smartctl 6.3 2014-07-26 r3976 [x86_64-linux-2.6.32-5-amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: SEAGATE
Product: ST900MM0006
Revision: LS08
Compliance: SPC-4
User Capacity: 900,185,481,216 bytes [900 GB]
Logical block size: 512 bytes
LB provisioning type: unreported, LBPME=-1, LBPRZ=0
Rotation Rate: 10000 rpm
Form Factor: 2.5 inches
Logical Unit id: 0x5000c500767033b3
Serial number: S0N1MEKG
Device type: disk
Transport protocol: SAS (SPL-3)
Local Time is: Wed Mar 4 13:17:30 2015 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Current Drive Temperature: 21 C
Drive Trip Temperature: 50 C
Manufactured in week 22 of year 2014
Specified cycle count over device lifetime: 10000
Accumulated start-stop cycles: 118
Specified load-unload count over device lifetime: 300000
Accumulated load-unload cycles: 314
Elements in grown defect list: 0
Vendor (Seagate) cache information
Blocks sent to initiator = 965779306
Blocks received from initiator = 2971611077
Blocks read from cache and sent to initiator = 403576599
Number of read and write commands whose size <= segment size = 11852771
Number of read and write commands whose size segment size = 121
Vendor (Seagate/Hitachi) factory information
number of hours powered up = 4833.13
number of minutes until next internal SMART test = 54
Error counter log:
Errors Corrected by Total Correction Gigabytes Total
ECC rereads/ errors algorithm processed uncorrected
fast | delayed rewrites corrected invocations [10^9 bytes] errors
read: 3785944895 0 0 3785944895 0 2403.727 0
write: 0 0 0 0 0 4069.649 0
verify: 3308284580 0 0 3308284580 0 15953.521 0
Non-medium error count: 0
SMART Self-test log
Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ]
Description number (hours)
# 1 Background short Completed 48 8 - [- - -]
# 2 Reserved(7) Completed 32 8 - [- - -]
# 3 Background short Completed 48 7 - [- - -]
Long (extended) Self Test duration: 5616 seconds [93.6 minutes]
有什么线索吗?我在这里遗漏了什么?如何获取 SMART 指标?
答案1
您无法从 RAID 阵列中提取 SMART 信息。阵列确实有 SMART 信息,即组成阵列的驱动器。
Dev sda 是 RAID,而不是单元 (sd0、sd1 / sda1、sdb1 等)。因此,请从磁盘单元(而不是阵列)中提取信息。