HP Proliant 服务器 DL180 g6 智能阵列 p410 致命错误

HP Proliant 服务器 DL180 g6 智能阵列 p410 致命错误

我有一台 HP PROLIANT 服务器 DL 180 G6。该服务器突然重启,有时一天重启两三次,有时两天后或七天后重启。(重启截图

我已经运行了 hp smart storage 管理员工具 (查看屏幕截图)。

ADU REPORT


ADU Version                             2.30.6.0
Diagnostic Module Version               8.3.6.0
Time Generated                          Friday January 20, 2017 2:22:11PM

Device Summary:
   Smart Array P410 in Embedded Slot

Consolidated Error Report:
   Controller: Smart Array P410 in Embedded Slot
      Message: An unknown cache error was detected.
   Controller: Smart Array P410 in Embedded Slot
      Message: The cache is permanently disabled.

Report for Smart Array P410 in Embedded Slot
--------------------------------------------

Smart Array P410 in Embedded Slot : Device Error Report

Device                            Severity Error                                
--------------------------------- -------- ------------------------------------ 
Smart Array P410 in Embedded Slot Warning  An unknown cache error was detected.
Smart Array P410 in Embedded Slot Critical The cache is permanently disabled.

答案1

没有更好的理由打电话给 HP 支持部门请求技术支持 上次我记得技术人员更换了智能阵列/RAID 控制器 问候

答案2

您的 RAID 缓存模块有缺陷,因此控制器完全禁用了写回缓存。这似乎不是简单的电池问题;可能是 DRAM 缓存内存本身坏了。

您自己无能为力,只能购买另一个相同的控制器并更换发生故障的控制器。但是,如果可以的话,请拨打 HP 支持电话并要求更换。

相关内容