我有一台 HP PROLIANT 服务器 DL 180 G6。该服务器突然重启,有时一天重启两三次,有时两天后或七天后重启。(重启截图)
我已经运行了 hp smart storage 管理员工具 (查看屏幕截图)。
ADU REPORT
ADU Version 2.30.6.0
Diagnostic Module Version 8.3.6.0
Time Generated Friday January 20, 2017 2:22:11PM
Device Summary:
Smart Array P410 in Embedded Slot
Consolidated Error Report:
Controller: Smart Array P410 in Embedded Slot
Message: An unknown cache error was detected.
Controller: Smart Array P410 in Embedded Slot
Message: The cache is permanently disabled.
Report for Smart Array P410 in Embedded Slot
--------------------------------------------
Smart Array P410 in Embedded Slot : Device Error Report
Device Severity Error
--------------------------------- -------- ------------------------------------
Smart Array P410 in Embedded Slot Warning An unknown cache error was detected.
Smart Array P410 in Embedded Slot Critical The cache is permanently disabled.
答案1
没有更好的理由打电话给 HP 支持部门请求技术支持 上次我记得技术人员更换了智能阵列/RAID 控制器 问候
答案2
您的 RAID 缓存模块有缺陷,因此控制器完全禁用了写回缓存。这似乎不是简单的电池问题;可能是 DRAM 缓存内存本身坏了。
您自己无能为力,只能购买另一个相同的控制器并更换发生故障的控制器。但是,如果可以的话,请拨打 HP 支持电话并要求更换。