我有一个运行 RAID-10 的 3ware RAID 控制器。
我有一个磁盘,目前有一个SMART-FAILURE
。我运行了/c0 rescan
,状态将更改为正常,然后返回到SMART-FAILURE
> /c0 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
------------------------------------------------------------------------------
u0 RAID-1 OK - - - 931.312 RiW OFF
u1 RAID-10 OK - - 256K 3725.25 RiW OFF
u3 SPARE OK - - - 931.505 - OFF
VPort Status Unit Size Type Phy Encl-Slot Model
------------------------------------------------------------------------------
p0 OK u0 931.51 GB SATA 0 - ST1000DM005 HD103SJ
p1 OK u0 931.51 GB SATA 1 - ST1000DM005 HD103SJ
p3 OK u1 931.51 GB SATA 3 - ST1000DM005 HD103SJ
p4 OK u1 931.51 GB SATA 4 - ST1000DM005 HD103SJ
p5 OK u1 931.51 GB SATA 5 - ST1000DM005 HD103SJ
p6 OK u1 931.51 GB SATA 6 - ST1000DM005 HD103SJ
p7 OK u1 931.51 GB SATA 7 - ST1000DM005 HD103SJ
p8 SMART-FAILURE u1 931.51 GB SATA 8 - ST1000DM005 HD103SJ
p9 OK u1 931.51 GB SATA 9 - ST1000DM005 HD103SJ
p10 OK u1 931.51 GB SATA 10 - ST1000DM005 HD103SJ
p11 OK u3 931.51 GB SATA 11 - ST1000DM005 HD103SJ
我已经对如何更换磁盘进行了一些研究,但找不到任何没有涉及如何用备用单元更换磁盘的文档。
如何用 u3 单元替换 p8 磁盘?
答案1
我移除了 p8 磁盘,u3 单元开始自行重建。这是自动发生的。