更换磁盘后 LSI Megaraid 发出蜂鸣声

更换磁盘后 LSI Megaraid 发出蜂鸣声

在我的 ESXi 服务器上,我必须更换 RAID 的物理磁盘。

现在磁盘已更换且重建完成,警报继续发出哔哔声,我不明白为什么,因为一切似乎都是最佳的:

/opt/lsi/MegaCLI # ./MegaCli -LDInfo -Lall -aALL


Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-6, Secondary-0, RAID Level Qualifier-3
Size                : 2.725 TB
Sector Size         : 512
Is VD emulated      : No
Parity Size         : 930.5 GB
State               : Optimal
Strip Size          : 256 KB
Number Of Drives    : 8
Span Depth          : 1
Default Cache Policy: WriteThrough, ReadAhead, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAhead, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
PI type: No PI

Is VD Cached: No


Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-6, Secondary-0, RAID Level Qualifier-3
Size                : 3.637 TB
Sector Size         : 512
Is VD emulated      : Yes
Parity Size         : 3.637 TB
State               : Optimal
Strip Size          : 256 KB
Number Of Drives    : 4
Span Depth          : 1
Default Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU
Current Cache Policy: WriteBack, ReadAhead, Cached, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Enabled
Encryption Type     : None
PI type: No PI

Is VD Cached: No

运行时./MegaCli -PDList -aALL指示没有媒体错误计数,但我的虚拟驱动器的物理驱动器:1 指示“其他错误计数:6”,我不知道如何获得有关这些错误的更多信息。

我知道我可以让这个闹钟静音,但如果我这样做,闹钟会在下次重启时重新启动。

有没有办法知道警报为什么会打开?有没有办法在重启后禁用它(当然,不能完全禁用这个警报,因为新的磁盘崩溃后必须打开它)。

谢谢

答案1

如果“复制回”功能已打开,就会发生这种情况。基本上,被替换的驱动器必须位于同一插槽中,否则它会一直发出哔哔声。在我看来,这是一个相当烦人的功能,所以我在我的服务器上禁用了“复制回”,如下所示: https://www.broadcom.com/support/knowledgebase/1211161502838/megaraid-controller-still-beeps-after-rebuild-completes-and-vd-i

相关内容