我的任务是配置 Windows 服务器以使用以下磁盘的分层存储
- 4 个 900 GB SSD
- 10 个 2.2TB HDD
SSD 层将使用具有 1 个冗余磁盘的奇偶校验进行配置,而 HHD 层将使用具有 2 个冗余磁盘的奇偶校验进行配置。
通过 powershell 配置时,我发现可以在两点设置物理磁盘冗余,即在创建存储层时和在创建虚拟磁盘时再次设置。
我想了解这个设置在这两点上的影响,以及是否有必要在虚拟磁盘级别进行设置,因为我之前已经设置过了。
我可以确认这-PhysicalDiskRedundancy
两个级别的设置都会影响虚拟磁盘的存储效率。
然后我创建了一个脚本来生成几个具有不同配置的虚拟磁盘来验证效果。
$SSD_Parity1 = New-StorageTier -FriendlyName SSD_Parity1 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType SSD -ProvisioningType Fixed -ResiliencySettingName Parity -PhysicalDiskRedundancy 1
$HDD_Parity1 = New-StorageTier -FriendlyName HDD_Parity1 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType HDD -ProvisioningType Fixed -ResiliencySettingName Parity -PhysicalDiskRedundancy 1
$SSD_Parity2 = New-StorageTier -FriendlyName SSD_Parity2 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType SSD -ProvisioningType Fixed -ResiliencySettingName Parity -PhysicalDiskRedundancy 2
$HDD_Parity2 = New-StorageTier -FriendlyName HDD_Parity2 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType HDD -ProvisioningType Fixed -ResiliencySettingName Parity -PhysicalDiskRedundancy 2
$SSD_Mirror1 = New-StorageTier -FriendlyName SSD_Mirror1 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType SSD -ProvisioningType Fixed -ResiliencySettingName Mirror -PhysicalDiskRedundancy 1
$HDD_Mirror1 = New-StorageTier -FriendlyName HDD_Mirror1 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType HDD -ProvisioningType Fixed -ResiliencySettingName Mirror -PhysicalDiskRedundancy 1
$SSD_Mirror2 = New-StorageTier -FriendlyName SSD_Mirror2 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType SSD -ProvisioningType Fixed -ResiliencySettingName Mirror -PhysicalDiskRedundancy 2
$HDD_Mirror2 = New-StorageTier -FriendlyName HDD_Mirror2 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType HDD -ProvisioningType Fixed -ResiliencySettingName Mirror -PhysicalDiskRedundancy 2
#$SSD_ParityExpectedCFG = New-StorageTier -FriendlyName SSD_Parity22 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType SSD -ProvisioningType Fixed -ResiliencySettingName Parity -PhysicalDiskRedundancy 1
#$HDD_ParityExpectedCFG = New-StorageTier -FriendlyName HDD_Parity22 -StoragePoolFriendlyName Dtaa -FaultDomainAwareness PhysicalDisk -MediaType HDD -ProvisioningType Fixed -ResiliencySettingName Parity -PhysicalDiskRedundancy 2
$Pairs =@($SSD_Parity1,$HDD_Parity1),($SSD_Parity2,$HDD_Parity2),($SSD_Mirror1,$HDD_Mirror1),($SSD_Mirror2,$HDD_Mirror2),($SSD_Mirror1,$HDD_Parity2)
$details = @()
$ErrorActionPreference = "Continue"
$disks += $Pairs | %{
$name = "$( $_[0].FriendlyName ) $($_[1].FriendlyName )"
New-VirtualDisk -FriendlyName "$name (default)" -StoragePoolFriendlyName DTAA -StorageTiers $($_[0]),$($_[1]) -StorageTierSizes 25GB,25GB #-FaultDomainAwareness PhysicalDisk
New-VirtualDisk -FriendlyName "$name (pd2-mirror)" -StoragePoolFriendlyName DTAA -StorageTiers $($_[0]),$($_[1]) -StorageTierSizes 25GB,25GB -ResiliencySettingName 'Mirror' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 2
New-VirtualDisk -FriendlyName "$name (pd1-mirror)" -StoragePoolFriendlyName DTAA -StorageTiers $($_[0]),$($_[1]) -StorageTierSizes 25GB,25GB -ResiliencySettingName 'Mirror' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 1
New-VirtualDisk -FriendlyName "$name (pd2-parity)" -StoragePoolFriendlyName DTAA -StorageTiers $($_[0]),$($_[1]) -StorageTierSizes 25GB,25GB -ResiliencySettingName 'Parity' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 2
New-VirtualDisk -FriendlyName "$name (pd1-parity)" -StoragePoolFriendlyName DTAA -StorageTiers $($_[0]),$($_[1]) -StorageTierSizes 25GB,25GB -ResiliencySettingName 'Parity' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 1
}
$disks += New-VirtualDisk -FriendlyName "NoTier (default)" -StoragePoolFriendlyName DTAA -Size 50GB
$disks += New-VirtualDisk -FriendlyName "NoTier (pd1-mirror)" -StoragePoolFriendlyName DTAA -Size 50GB -ResiliencySettingName 'Mirror' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 1
$disks += New-VirtualDisk -FriendlyName "NoTier (pd2-mirror)" -StoragePoolFriendlyName DTAA -Size 50GB -ResiliencySettingName 'Mirror' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 2
$disks += New-VirtualDisk -FriendlyName "NoTier (pd1-parity)" -StoragePoolFriendlyName DTAA -Size 50GB -ResiliencySettingName 'Parity' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 1
$disks += New-VirtualDisk -FriendlyName "NoTier (pd2-parity)" -StoragePoolFriendlyName DTAA -Size 50GB -ResiliencySettingName 'Parity' -FaultDomainAwareness PhysicalDisk -PhysicalDiskRedundancy 2
脚本的输出
FriendlyName ResiliencySettingName FaultDomainRedundancy OperationalStatus HealthStatus Size FootprintOnPool StorageEfficiency
------------ --------------------- --------------------- ----------------- ------------ ---- --------------- -----------------
SSD_Parity1 HDD_Parity1 (default) OK Healthy 50 GB 72.25 GB 69.20%
SSD_Parity1 HDD_Parity1 (pd2-mirror) OK Healthy 51 GB 156.75 GB 32.54%
SSD_Parity1 HDD_Parity1 (pd1-mirror) OK Healthy 50 GB 102.5 GB 48.78%
SSD_Parity1 HDD_Parity1 (pd2-parity) OK Healthy 50 GB 92.75 GB 53.91%
SSD_Parity1 HDD_Parity1 (pd1-parity) OK Healthy 50 GB 72.25 GB 69.20%
SSD_Parity2 HDD_Parity2 (default) OK Healthy 50 GB 92.75 GB 53.91%
SSD_Parity2 HDD_Parity2 (pd2-mirror) OK Healthy 51 GB 156.75 GB 32.54%
SSD_Parity2 HDD_Parity2 (pd1-mirror) OK Healthy 50 GB 102.5 GB 48.78%
SSD_Parity2 HDD_Parity2 (pd2-parity) OK Healthy 50 GB 92.75 GB 53.91%
SSD_Parity2 HDD_Parity2 (pd1-parity) OK Healthy 50 GB 72.25 GB 69.20%
SSD_Mirror1 HDD_Mirror1 (default) OK Healthy 50 GB 102.5 GB 48.78%
SSD_Mirror1 HDD_Mirror1 (pd2-mirror) OK Healthy 51 GB 156.75 GB 32.54%
SSD_Mirror1 HDD_Mirror1 (pd1-mirror) OK Healthy 50 GB 102.5 GB 48.78%
SSD_Mirror1 HDD_Mirror1 (pd2-parity) OK Healthy 50 GB 92.75 GB 53.91%
SSD_Mirror1 HDD_Mirror1 (pd1-parity) OK Healthy 50 GB 72.25 GB 69.20%
SSD_Mirror2 HDD_Mirror2 (default) OK Healthy 51 GB 156.75 GB 32.54%
SSD_Mirror2 HDD_Mirror2 (pd2-mirror) OK Healthy 51 GB 156.75 GB 32.54%
SSD_Mirror2 HDD_Mirror2 (pd1-mirror) OK Healthy 50 GB 102.5 GB 48.78%
SSD_Mirror2 HDD_Mirror2 (pd2-parity) OK Healthy 50 GB 92.75 GB 53.91%
SSD_Mirror2 HDD_Mirror2 (pd1-parity) OK Healthy 50 GB 72.25 GB 69.20%
SSD_Mirror1 HDD_Parity2 (default) OK Healthy 50 GB 93.25 GB 53.62%
SSD_Mirror1 HDD_Parity2 (pd2-mirror) OK Healthy 51 GB 156.75 GB 32.54%
SSD_Mirror1 HDD_Parity2 (pd1-mirror) OK Healthy 50 GB 102.5 GB 48.78%
SSD_Mirror1 HDD_Parity2 (pd2-parity) OK Healthy 50 GB 92.75 GB 53.91%
SSD_Mirror1 HDD_Parity2 (pd1-parity) OK Healthy 50 GB 72.25 GB 69.20%
NoTier (default) Mirror 1 OK Healthy 56 GB 114.5 GB 48.91%
NoTier (pd1-mirror) Mirror 1 OK Healthy 56 GB 114.5 GB 48.91%
NoTier (pd2-mirror) Mirror 2 OK Healthy 52 GB 159.75 GB 32.55%
NoTier (pd1-parity) Parity 1 OK Healthy 52 GB 68.5 GB 75.91%
NoTier (pd2-parity) Parity 2 OK Healthy 56 GB 82.25 GB 68.09%
虽然这证明在两个地方设置磁盘冗余都有效,但我还没有找到原因。