\Device\Harddisk11\DR26 出现错误,但磁盘 11 不存在

\Device\Harddisk11\DR26 出现错误,但磁盘 11 不存在

在 Windows 2008R2 服务器上,我在事件查看器中收到此消息:

Log Name:      System
Source:        Disk
Date:          7/3/2013 4:25:54 AM
Event ID:      51
Task Category: None
Level:         Warning
Keywords:      Classic
User:          N/A
Description:
An error was detected on device \Device\Harddisk11\DR26 during a paging operation.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
  <System>
    <Provider Name="Disk" />
    <EventID Qualifiers="32772">51</EventID>
    <Level>3</Level>
    <Task>0</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime="2013-07-03T08:25:54.828401000Z" />
    <EventRecordID>115066</EventRecordID>
    <Channel>System</Channel>
    <Security />
  </System>
  <EventData>
    <Data>\Device\Harddisk11\DR26</Data>
    <Binary>030080000100000000000000330004802D0100000E0000C000000000000000000000000000000000BE009A0500000000FFFFFFFF010000005800000802000008FD200A1242032040000200003C0000001080838780FAFFFF483DF28780FAFFFF0000000000000000D0285A0281FAFFFF0000000000000000008841060000000028000641880000000100000000000000000000000000000000000000000000000000000000000000</Binary>
  </EventData>
</Event>

但是,此服务器上没有磁盘 11。磁盘停止在 10。

磁盘管理 mmc 显示磁盘 9、10 和 DVD 驱动器

此特定服务器是集群中的 Hyper-V 主机。所有磁盘均为 CSV 磁盘或直通磁盘,均由 iSCSI 支持。

我如何识别这是哪个驱动器?

wmic没有列出驱动器:

Caption                                     DeviceID             Model                                       Partitions  Size
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE5   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           2418923243520
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE9   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           1069286400
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE10  LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           1759214661120
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE4   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           1979117521920
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE7   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           80525491200
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE8   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           536864025600
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE2   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           536864025600
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE3   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           536864025600
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE1   LEFTHAND iSCSIDisk  Multi-Path Disk Device  1           322118415360
LEFTHAND iSCSIDisk  Multi-Path Disk Device  \\.\PHYSICALDRIVE6   LEFTHAND iSCSIDisk  Multi-Path Disk Device  0           1069286400
HP LOGICAL VOLUME SCSI Disk Device          \\.\PHYSICALDRIVE0   HP LOGICAL VOLUME SCSI Disk Device          2           220122071040

答案1

这有点摇摆但你有没有尝试重新编译 iSCSI金属有机酸酯文件?我遇到过类似的行为,NetApp 的 SnapDrive 无法枚举特定服务器上的所有 iSCSI 驱动器。这博客指出了这个KB2001997

尝试将此服务器上的以下 WMI 查询的结果与另一个已知良好的查询结果进行比较:

Get-WmiObject -NameSpace Root\WMI MSiSCSIInitiator_PersistentDevices

相关内容