print_req_error: I/O 错误,dev sdb,扇区 882159520

print_req_error: I/O 错误,dev sdb,扇区 882159520

过了一段时间,我回到托管 ubuntu nas 的 esxi 服务器,单击查看终端窗口,发现几条消息,如标题中所示,这些消息表示服务器上随机磁盘上的随机扇区。甚至在一块 ssd 中。几周前,当我建立新的虚拟化服务器时,对这些磁盘进行了测试,一切正常。这是上述消息的磁盘智能输出,我没有看到任何严重错误:

# smartctl -a /dev/sdb
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-36-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.14 (AF)
Device Model:     ST2000DM001-1ER164
Serial Number:    Z4Z0AW14
LU WWN Device Id: 5 000c50 06756268a
Firmware Version: CC43
User Capacity:    2.000.398.934.016 bytes [2,00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Nov  2 20:45:56 2018 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (   97) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 234) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x1085) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   115   099   006    Pre-fail  Always       -       84913608
  3 Spin_Up_Time            0x0003   096   094   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   094   094   020    Old_age   Always       -       6805
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   064   060   030    Pre-fail  Always       -       3127908
  9 Power_On_Hours          0x0032   074   074   000    Old_age   Always       -       23041
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   020    Old_age   Always       -       1191
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0 0 0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   064   044   045    Old_age   Always   In_the_past 36 (Min/Max 22/42 #2)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       892
193 Load_Cycle_Count        0x0032   088   088   000    Old_age   Always       -       24858
194 Temperature_Celsius     0x0022   036   056   000    Old_age   Always       -       36 (0 13 0 0 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       4466h+29m+46.336s
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       8413369205
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       33804423107

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     22533         -
# 2  Short offline       Completed without error       00%     22529         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

ubuntu VM 从通过的 LSI 控制器获取磁盘。这会是 esxi 主机中的问题吗?我担心写入时会弄乱磁盘内容。

相关内容