系统非常慢,正在尝试找到瓶颈

系统非常慢,正在尝试找到瓶颈

我在 Sony VIAO E 系列 VPCEH16EN、4GB RAM、320 GB HDD、Intel Core i3-2310M 处理器 2.10GHz 上安装了 Ubuntu 12.10。它与 Windows7 一起双启动。

我发现系统响应非常慢,任何视频在播放过程中都会卡住。你能帮我找出瓶颈在哪里吗?以下是hdparm和的输出smartctl

------------- HDPARM -------------------
anil@anil-ubuntu:~$ sudo hdparm -Tt /dev/sda6 
/dev/sda6:
 Timing cached reads:     2 MB in  3.51 seconds = 584.17 kB/sec
 Timing buffered disk reads: 160 MB in  3.02 seconds =  52.91 MB/sec
anil@anil-ubuntu:~$ 
-----------------------------------------

-------------- SMARTCTL -----------------
anil@anil-ubuntu:~$ sudo smartctl -a /dev/sda6
smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.5.0-25-generic] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MK3265GSXN
Serial Number:    419CD3X3B
LU WWN Device Id: 5 000039 33ab02a3c
Firmware Version: GH012H
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Feb 28 23:08:07 2013 IST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                    was never started.
                    Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                    without error or no self-test has ever 
                    been run.
Total time to complete Offline 
data collection:        (  120) seconds.
Offline data collection
capabilities:            (0x5b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    No Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    General Purpose Logging supported.
Short self-test routine 
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    (  95) minutes.
SCT capabilities:          (0x003d) SCT Status supported.
                    SCT Error Recovery Control supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       -       1258
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       2560
  5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       -       47
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0032   088   088   000    Old_age   Always       -       4940
 10 Spin_Retry_Count        0x0033   150   100   030    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       2553
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       118
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       169
193 Load_Cycle_Count        0x0032   099   099   000    Old_age   Always       -       13993
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       43 (Min/Max 20/47)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       5
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
220 Disk_Shift              0x0002   100   100   000    Old_age   Always       -       19
222 Loaded_Hours            0x0032   091   091   000    Old_age   Always       -       3918
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
224 Load_Friction           0x0022   100   100   000    Old_age   Always       -       0
226 Load-in_Time            0x0026   100   100   000    Old_age   Always       -       245
240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      -       0
SMART Error Log Version: 1
ATA Error Count: 108 (device log contains only the most recent five errors)
    CR = Command Register [HEX]
    FR = Features Register [HEX]
    SC = Sector Count Register [HEX]
    SN = Sector Number Register [HEX]
    CL = Cylinder Low Register [HEX]
    CH = Cylinder High Register [HEX]
    DH = Device/Head Register [HEX]
    DC = Device Command Register [HEX]
    ER = Error register [HEX]
    ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 108 occurred at disk power-on lifetime: 3337 hours (139 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 4a 6a 9d bb 64  Error: WP at LBA = 0x04bb9d6a = 79404394
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 08 58 f0 f6 b8 40 00      03:49:54.536  WRITE FPDMA QUEUED
  61 08 50 00 f7 b8 40 00      03:49:54.536  WRITE FPDMA QUEUED
  60 00 48 98 9c bb 40 00      03:49:54.535  READ FPDMA QUEUED
  61 38 40 c8 0b b9 40 00      03:49:54.535  WRITE FPDMA QUEUED
  61 02 38 88 3a 39 40 00      03:49:54.535  WRITE FPDMA QUEUED
Error 107 occurred at disk power-on lifetime: 3337 hours (139 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 f2 6a 9d bb 64  Error: WP at LBA = 0x04bb9d6a = 79404394
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 08 f8 68 c9 65 40 00      03:49:50.336  WRITE FPDMA QUEUED
  60 00 f0 98 9c bb 40 00      03:49:50.335  READ FPDMA QUEUED
  61 08 e8 28 71 61 40 00      03:49:50.335  WRITE FPDMA QUEUED
  61 18 e0 08 c8 61 40 00      03:49:50.335  WRITE FPDMA QUEUED
  61 20 d8 d8 90 6c 40 00      03:49:50.335  WRITE FPDMA QUEUED
Error 106 occurred at disk power-on lifetime: 3337 hours (139 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 62 6a 9d bb 64  Error: WP at LBA = 0x04bb9d6a = 79404394
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 08 70 f8 f6 b8 40 00      03:49:46.159  WRITE FPDMA QUEUED
  61 08 68 08 f7 b8 40 00      03:49:46.159  WRITE FPDMA QUEUED
  60 00 60 98 9c bb 40 00      03:49:46.157  READ FPDMA QUEUED
  61 08 58 c0 0b b9 40 00      03:49:46.157  WRITE FPDMA QUEUED
  61 08 50 e8 38 62 40 00      03:49:46.157  WRITE FPDMA QUEUED
Error 105 occurred at disk power-on lifetime: 3337 hours (139 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 aa 6a 9d bb 64  Error: WP at LBA = 0x04bb9d6a = 79404394
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 08 00 28 87 7e 40 00      03:49:41.973  WRITE FPDMA QUEUED
  61 08 f8 78 7d 7e 40 00      03:49:41.972  WRITE FPDMA QUEUED
  61 08 f0 40 7d 7e 40 00      03:49:41.972  WRITE FPDMA QUEUED
  61 08 e8 88 72 7e 40 00      03:49:41.972  WRITE FPDMA QUEUED
  61 08 e0 d0 5e 7e 40 00      03:49:41.972  WRITE FPDMA QUEUED
Error 104 occurred at disk power-on lifetime: 3337 hours (139 days + 1 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 52 6a 9d bb 64  Error: WP at LBA = 0x04bb9d6a = 79404394
  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 08 78 f0 04 bd 40 00      03:49:37.805  WRITE FPDMA QUEUED
  61 08 70 20 03 bd 40 00      03:49:37.804  WRITE FPDMA QUEUED
  61 08 68 08 03 bd 40 00      03:49:37.804  WRITE FPDMA QUEUED
  61 10 60 e8 02 bd 40 00      03:49:37.803  WRITE FPDMA QUEUED
  61 03 58 d8 f2 6f 40 00      03:49:37.803  WRITE FPDMA QUEUED
SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
--------------------------------------------------------------------

答案1

磁盘的 SMART 数据显示您的硬盘出现故障。我会备份磁盘中可能存在的重要信息并尽快更换。

一切类型: 失败前警告应该明确指出,除了104、105、106、107 和 108报告中的错误smartctl

palimpsest您还可以使用( )检查硬盘状况(由 SMART 数据显示)Disk Utility并在那里检查状态

在此处输入图片描述

相关内容