我的笔记本电脑出现有线问题。它工作正常,但几乎每小时都会冻结屏幕。当我强制关闭并再次启动时,我看到类似以下的问题: 在此输入图像描述

我找到的唯一解决方案是将笔记本电脑翻转几秒钟,然后再次启动。这帮助我看到我的 Ubuntu 正常工作,没有这些 FS 问题。

更新: 这是 smartctl 输出:

smartctl 6.5 2016-01-24 r4214 [i686-linux-4.15.0-32-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Laptop SSHD
Device Model:     ST500LM000-SSHD-8GB
Serial Number:    W761F5WC
LU WWN Device Id: 5 000c50 07c440eb8
Firmware Version: LIV5
User Capacity:    500 107 862 016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Aug 17 14:37:51 2018 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                    was completed without error.
                    Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                    without error or no self-test has ever 
                    been run.
Total time to complete Offline 
data collection:        (  128) seconds.
Offline data collection
capabilities:            (0x7b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    General Purpose Logging supported.
Short self-test routine 
recommended polling time:    (   1) minutes.
Extended self-test routine
recommended polling time:    (  96) minutes.
Conveyance self-test routine
recommended polling time:    (   2) minutes.
SCT capabilities:          (0x1081) SCT Status supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   114   099   034    Pre-fail  Always       -       81759080
  3 Spin_Up_Time            0x0003   098   098   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   097   097   020    Old_age   Always       -       3865
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   072   060   030    Pre-fail  Always       -       163745195646
  9 Power_On_Hours          0x0032   080   080   000    Old_age   Always       -       17649 (115 151 0)
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   096   096   020    Old_age   Always       -       4175
184 End-to-End_Error        0x0032   096   096   099    Old_age   Always   FAILING_NOW 4
187 Reported_Uncorrect      0x0032   098   098   000    Old_age   Always       -       2
188 Command_Timeout         0x0032   100   094   000    Old_age   Always       -       25770197149
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   058   036   045    Old_age   Always   In_the_past 42 (Min/Max 42/46 #389)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       1213
193 Load_Cycle_Count        0x0032   098   098   000    Old_age   Always       -       4834
194 Temperature_Celsius     0x0022   042   064   000    Old_age   Always       -       42 (0 12 0 0 0)
196 Reallocated_Event_Count 0x000f   080   080   030    Pre-fail  Always       -       17711 (44104 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 7 (device log contains only the most recent five errors)
    CR = Command Register [HEX]
    FR = Features Register [HEX]
    SC = Sector Count Register [HEX]
    SN = Sector Number Register [HEX]
    CL = Cylinder Low Register [HEX]
    CH = Cylinder High Register [HEX]
    DH = Device/Head Register [HEX]
    DC = Device Command Register [HEX]
    ER = Error register [HEX]
    ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 7 occurred at disk power-on lifetime: 16948 hours (706 days + 4 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 ff ff ff 4f 00      00:00:25.320  READ FPDMA QUEUED
  60 00 20 ff ff ff 4f 00      00:00:25.319  READ FPDMA QUEUED
  60 00 60 88 da 7f 41 00      00:00:25.309  READ FPDMA QUEUED
  60 00 20 ff ff ff 4f 00      00:00:25.288  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:00:25.284  READ FPDMA QUEUED

Error 6 occurred at disk power-on lifetime: 966 hours (40 days + 6 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 10 c5 a5 00  Error: UNC at LBA = 0x00a5c510 = 10863888

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 88 79 42 43 00      00:00:18.239  READ FPDMA QUEUED
  60 00 08 80 79 42 43 00      00:00:18.239  READ FPDMA QUEUED
  60 00 a8 10 c8 84 40 00      00:00:18.237  READ FPDMA QUEUED
  60 00 08 78 79 42 43 00      00:00:18.237  READ FPDMA QUEUED
  60 00 00 e0 c6 84 40 00      00:00:18.237  READ FPDMA QUEUED

Error 5 occurred at disk power-on lifetime: 966 hours (40 days + 6 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 10 c5 a5 00  Error: UNC at LBA = 0x00a5c510 = 10863888

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 28 00 48 f8 40 00      00:00:13.615  READ FPDMA QUEUED
  60 00 08 08 0e 44 40 00      00:00:13.609  READ FPDMA QUEUED
  60 00 18 60 d0 e6 40 00      00:00:13.608  READ FPDMA QUEUED
  60 00 08 b8 a8 e6 40 00      00:00:13.608  READ FPDMA QUEUED
  60 00 28 10 9b e6 40 00      00:00:13.607  READ FPDMA QUEUED

Error 4 occurred at disk power-on lifetime: 32 hours (1 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 76 9d b6 01  Error: UNC at LBA = 0x01b69d76 = 28745078

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 80 60 9d b6 41 00      00:01:10.856  READ FPDMA QUEUED
  61 00 08 68 89 59 40 00      00:01:10.747  WRITE FPDMA QUEUED
  61 00 08 88 f6 3c 40 00      00:01:10.747  WRITE FPDMA QUEUED
  2f 00 01 10 00 00 20 00      00:01:10.494  READ LOG EXT
  60 00 40 c8 25 4c 41 00      00:01:10.441  READ FPDMA QUEUED

Error 3 occurred at disk power-on lifetime: 32 hours (1 days + 8 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 76 9d b6 01  Error: UNC at LBA = 0x01b69d76 = 28745078

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 80 60 9d b6 41 00      00:00:53.242  READ FPDMA QUEUED
  61 00 80 40 ba 44 41 00      00:00:53.241  WRITE FPDMA QUEUED
  61 00 10 10 f7 86 40 00      00:00:53.241  WRITE FPDMA QUEUED
  60 00 40 98 b7 1e 42 00      00:00:53.216  READ FPDMA QUEUED
  60 00 08 60 9d b6 41 00      00:00:53.169  READ FPDMA QUEUED

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Vendor (0x50)       Completed without error       00%         1         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

我在启动时做了一个 FSCK 来解决这个问题,但没有帮助。你有什么解决办法吗?

答案1

立即备份

去购买额外的外部 HDD/SSD 并制作完整的CloneZilla 直播立即备份!以下参数最能表明您的驱动器即将出现故障:

184 端到端错误 0x0032 096 096 099 Old_age 始终 FAILING_NOW 4

尤其是作为您已经遇到这个问题一个月了:众所周知,HDD 不会立即死亡,但会给您足够的警告,例如点击声、随机错误等,而 SSD 会在没有警告的情况下突然死亡,除非您定期测量其 SMART 状态。

驱动器的经验法则是:

  • HDD 会像癌症一样缓慢而痛苦地死亡
  • SSD 突然死亡,就像心脏病发作一样

答案2

无法回答。

如果您的系统不稳定,因此无法正常关闭,则出现文件系统错误(随机出现,因为它取决于崩溃时的磁盘活动)被认为是正常的。

这不是文件系统问题,也不是 fsck 问题,您必须首先修复导致系统冻结的任何问题。

答案3

根据smartctl输出,您的驱动器现在失败了

对其上的所有内容进行单独备份。不要覆盖任何以前的备份(某些文件可能已经损坏,我们不想覆盖好的备份)。

然后用新的驱动器更换驱动器,并开始将新的备份与最后一次已知的良好备份进行比较,看看有多少损坏。