强制重建 HP 智能阵列中的 LUN

强制重建 HP 智能阵列中的 LUN

我的服务器有一个驱动器发生故障,还有一个驱动器处于预测故障状态。我更换了发生故障的驱动器,然后它正在重建。

root@linux:~ # hpacucli ctrl all show config

Smart Array E200 in Slot 3           (sn: PA6C9%%BFTWZMV)

   array A (SAS, Unused Space: 0 MB)

      logicaldrive 1 (410.1 GB, RAID 5, Recovering, 1.4% complete)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, Predictive Failure)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, Rebuilding)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK)
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK)

现在 LUN 卡在“准备重建”状态。除了重新启动服务器,我还能做什么?

root@linux:~ # hpacucli ctrl all show config

Smart Array E200 in Slot 3           (sn: PA6C9%%BFTWZMV)

   array A (SAS, Unused Space: 0 MB)

      logicaldrive 1 (410.1 GB, RAID 5, Ready for Rebuild)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, Predictive Failure)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, Predictive Failure)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK)
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK)

答案1

在此上下文中,“准备重建”意味着无法启动重建。查看您的阵列配置实用程序输出,这是因为需要进行奇偶校验的其他驱动器之一也发生故障。基本上,RAID 5 阵列中有两个发生故障的驱动器。这是不使用没有在线备用驱动器的 RAID 的一个很好的理由。在这种情况下,您唯一的永久解决方案是从驱动器中提取数据并恢复。

您可以尝试重新启动(或电源循环)。也许这会快速启动该过程(过去我曾成功过一两次)。如果您有 HP 支持,您还可以提取 ACU 诊断程序以查看停滞重建背后的具体原因。