SMART - 预测故障计数

SMART - 预测故障计数

我正在使用 MegaCLI 监控我的 IBM ServeRAID M5015 控制器的 RAID 状态,我在其中一个磁盘上有以下信息:

Enclosure Device ID: 252
Slot Number: 6
Enclosure position: 0
Device Id: 14
Sequence Number: 2
Media Error Count: 32
Other Error Count: 0
Predictive Failure Count: 18
Last Predictive Failure Event Seq Number: 8119
PD Type: SAS
Raw Size: 279.396 GB [0x22ecb25c Sectors]
Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]
Coerced Size: 278.464 GB [0x22cee000 Sectors]
Firmware state: Online, Spun Up
SAS Address(0): 0x5000c50042c319c9
SAS Address(1): 0x0
Connected Port Number: 5(path0)
Inquiry Data: IBM-ESXSST9300653SS     B6336XN04HC10525B633
IBM FRU/CRU: 81Y9671
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive:  Not Certified
Drive Temperature :33 Celsius

这到底是什么意思?我找不到确切的描述,有没有办法了解更多详细信息?RAID 阵列处于最佳状态。

介质错误计数:三十二

预测故障计数:18

有没有办法通过 CLI 打开前面的 LED,以便我物理上知道需要更换哪个磁盘?

答案1

您的磁盘有错误。聪明的代表自我监测、分析和报告技术

您提到的具体错误与驱动器的机械性能下降有关。您可以使用此报告从 IBM 获得保修更换。驱动器最终将出现故障。

答案2

来自 Seagate 文档:

预测失败

当驱动器在一段时间内性能不可接受时,SMART 会发出预测性故障信号。固件会持续计数每个属性的错误率不可接受的次数。为此,每次错误率不可接受时,计数器都会递增,而错误率可接受时,计数器会递减(不超过零)。如果计数器持续递增,以至于达到预测阈值,则会发出预测性故障信号。此计数器称为故障

历史计数器。每个属性都有一个单独的故障历史计数器。

按照以下步骤定位故障磁盘:

MegaCli -PdLocate -start -physdrv\[E:S] -aA
  • E :外壳
  • S :插槽
  • A:适配器

答案3

此时驱动器已发生物理故障。现在最需要担心的是妥善备份数据,并制定尽快更换驱动器的计划。

相关内容