我的问题:
使用直通电缆将 FastEthernet0 连接到 Catalyst 交换机后,线路协议短暂启动,然后关闭。接口也关闭,现在我在 show ip int brief 上看到以下内容:
Interface IP-Address OK? Method Status Protocol
FastEthernet0 unassigned YES unset down down
我在此声明,物理连接已中断,并且一定是端口或电缆有问题。
尝试过的解决方案:
Use a different cable
Use a different switch
Use a different port
Check Duplex settings and port speed
问题仍然存在,所以我不明白问题可能出在哪里,可能是交换机上的端口安全性吗?(我无法访问交换机,我正在远程执行此操作)
有人知道解决办法吗?
编辑:日志显示连接到交换机时发生的情况:
000072: *Mar 21 01:26:48.655: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up
000073: *Mar 21 01:26:48.659: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan10, changed state to up
000074: *Mar 21 01:26:49.651: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to up
000075: *Mar 21 01:26:50.179: %DTP-5-NONTRUNKPORTON: Port Fa0 has become non-trunk
000076: *Mar 21 01:26:50.679: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
000077: *Mar 21 01:26:50.679: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan10, changed state to down
000078: *Mar 21 01:26:51.679: %LINK-3-UPDOWN: Interface FastEthernet0, changed state to down
先感谢您。
答案1
正如您所怀疑的,端口安全(MAC 地址限制)将导致路由器连接然后立即断开连接。
(原因是,它以电方式连接,但不允许发送流量——第一个以太网数据包将被拒绝,并且交换机将端口置于关闭状态)
如果您可以选择在路由器上启用调试日志记录,请这样做。