查看 HP Smart Array 固件版本的最快方法是什么(最好是 GUI 版本)?我应该在 Windows 中查找它还是可以通过 iLO 查看?
答案1
如果您安装了 HP Management Agents,则该hpacucli
实用程序(作为阵列配置软件将提供您需要的所有控制器信息。对于 Windows 2003,下载此命令行工具包 或者这,用于 GUI。
该ctrl all show config detail
指令将输出类似以下内容的内容:
=> ctrl all 显示配置详细信息
Smart Array P410i in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: 50123456789ABCDE
Cache Serial Number: PBCDF0BRHYI032
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Chassis Slot:
Hardware Revision: Rev C
Firmware Version: 5.12
Rebuild Priority: High
Expand Priority: High
Surface Scan Delay: 15 secs
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: OK
Accelerator Ratio: 25% Read / 75% Write
Drive Write Cache: Enabled
Total Cache Size: 1024 MB
No-Battery Write Cache: Enabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Array: A
Interface Type: SAS
Unused Space: 0 MB
Status: OK