随着夏季气温逐渐升高,我的服务器越来越多地进入热保护关闭状态,因为温度传感器#21 已达到临界水平(58*C),正如 ILO 所报告的。
风扇都运转正常,但不幸的是,服务器不在气候控制室内,我对环境温度无能为力。但是,如果我知道传感器 #21 在哪里,我可以尝试改善该区域周围的气流。如果是 IC,我可以添加/加强散热器以改善冷却效果。
有人知道那个传感器在哪里吗?
编辑:
夜间级别:
Location Status Reading Thresholds
Temp 1: System Zone Ok 15C Caution: 42C; Critical:47C
Temp 2 (CPU 1): System 1 Ok 40C Caution: 82C; Critical:83C
Temp 3 (CPU 2): System 2 Ok 40C Caution: 82C; Critical:83C
Temp 4: Memory Zone Ok 37C Caution: 87C; Critical:92C
Temp 5: Memory Zone Ok 41C Caution: 87C; Critical:92C
Temp 6: System Zone n/a n/a Caution: 99C; Critical:99C
Temp 7: System Zone n/a n/a Caution: 99C; Critical:99C
Temp 8 (MemB0): Memory Zone Ok 34C Caution: 62C; Critical:67C
Temp 9 (MemB0): Memory Zone Ok 34C Caution: 61C; Critical:66C
Temp 10 (MemB0): Memory Zone Ok 33C Caution: 61C; Critical:66C
Temp 12 (MemB1): Memory Zone Ok 38C Caution: 66C; Critical:71C
Temp 13 (MemB1): Memory Zone Ok 39C Caution: 65C; Critical:70C
Temp 14 (MemB1): Memory Zone Ok 38C Caution: 70C; Critical:75C
Temp 15: System Zone Ok 40C Caution: 57C; Critical:62C
Temp 16: System Zone Ok 33C Caution: 50C; Critical:55C
Temp 17: System Zone Ok 35C Caution: 58C; Critical:63C
Temp 18: System Zone Ok 45C Caution: 110C; Critical:115C
Temp 19: System Zone Ok 41C Caution: 57C; Critical:62C
Temp 20: System Zone Ok 42C Caution: 53C; Critical:58C
Temp 21: System Zone Ok 49C Caution: 53C; Critical:58C
Temp 22 (PCIR): I/O Board Zone n/a n/a Caution: 99C; Critical:99C
Temp 23 (PCIR): I/O Board Zone n/a n/a Caution: 99C; Critical:99C
Temp 24 (PCIR): I/O Board Zone n/a n/a Caution: 99C; Critical:99C
Temp 25 (PCIR): I/O Board Zone n/a n/a Caution: 99C; Critical:99C
Temp 26: Storage Zone Ok 0C Caution: 99C; Critical:99C
Temp 27: Storage Zone Ok 0C Caution: 99C; Critical:99C
Temp 28: Storage Zone Ok 0C Caution: 99C; Critical:99C
Temp 29: Storage Zone Ok 0C Caution: 99C; Critical:99C
Temp 30: Storage Zone Ok 0C Caution: 99C; Critical:99C
Temp 31: Storage Zone Ok 0C Caution: 99C; Critical:99C
提前谢谢了。
答案1
21 号传感器是什么重要吗?你实际上会怎么做?做关于它?
你能检查一下环境温度吗?你能控制环境温度以保持在合理范围内吗?你绝对当然你没有一个失败的粉丝吗?
- 编辑 -
确保所有组件的固件都是最新的是有意义的。对您来说,这意味着您的系统 BIOS、ILO、RAID 控制器、NIC、背板和磁盘。这些都可以由用于 ProLiant 可启动 DVD 的 HP 支持包。请下载并运行。
检查服务器上的内部健康 LED。如果您运行的是受支持的 Linux 或 Windows 版本,请安装 HP 管理代理并检查输出hplog -t
以获取温度传感器信息。标准 DL180 G6 配置的输出如下所示。将您的结果与我的结果进行关联:
注意:本系统有四个风扇
# hplog -f
ID TYPE LOCATION STATUS REDUNDANT FAN SPEED
1 Var. Speed System Board Normal N/A Normal ( 55)
2 Var. Speed System Board Normal N/A Normal ( 59)
3 Var. Speed System Board Normal N/A Normal ( 63)
4 Var. Speed System Board Normal N/A Normal ( 53)
# hplog -t
ID TYPE LOCATION STATUS CURRENT THRESHOLD
1 Basic Sensor Mem. Brd. (1) Normal 78F/ 26C 188F/ 87C
2 Basic Sensor Mem. Brd. (1) Normal 78F/ 26C 188F/ 87C
3 Basic Sensor Mem. Brd. (1) Normal 82F/ 28C 188F/ 87C
4 Basic Sensor Mem. Brd. (1) Absent ---F/---C ---F/---C
5 Basic Sensor Mem. Brd. (1) Normal 80F/ 27C 188F/ 87C
6 Basic Sensor Mem. Brd. (1) Absent ---F/---C ---F/---C
7 Basic Sensor Mem. Brd. (1) Normal 104F/ 40C 203F/ 95C
8 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
9 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
10 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
11 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
12 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
13 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
14 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C
15 Basic Sensor System Board Absent ---F/---C ---F/---C
16 Basic Sensor System Board Absent ---F/---C ---F/---C
17 Basic Sensor Ambient Normal 71F/ 22C 140F/ 60C
18 Basic Sensor Ambient Normal 80F/ 27C 158F/ 70C
19 Basic Sensor System Board Normal 68F/ 20C 233F/112C
20 Basic Sensor System Board Normal 86F/ 30C 174F/ 79C
21 Basic Sensor System Board Normal 73F/ 23C 140F/ 60C
22 Basic Sensor System Board Normal 75F/ 24C 143F/ 62C
23 Basic Sensor System Board Normal 75F/ 24C 143F/ 62C
24 Basic Sensor System Board Normal 71F/ 22C 143F/ 62C
25 Basic Sensor System Board Normal 71F/ 22C 172F/ 78C
26 Basic Sensor System Board Normal 71F/ 22C 172F/ 78C
27 Basic Sensor System Board Normal 71F/ 22C 172F/ 78C
28 Basic Sensor System Board Normal 77F/ 25C 185F/ 85C
29 Basic Sensor System Board Normal 75F/ 24C 185F/ 85C
30 Basic Sensor System Board Normal 77F/ 25C 185F/ 85C
31 Basic Sensor System Board Normal 84F/ 29C 159F/ 71C
32 Basic Sensor System Board Normal 86F/ 30C 176F/ 80C
33 Basic Sensor System Board Normal 68F/ 20C 140F/ 60C
34 Basic Sensor System Board Normal 68F/ 20C 140F/ 60C
35 Basic Sensor System Board Normal 107F/ 42C 230F/110C