HP Proliant DL360p Gen8服务器故障硬盘更换

HP Proliant DL360p Gen8服务器故障硬盘更换

我的 HP Proliant DL360p Gen8 上有一块磁盘出现故障,该磁盘配有 p420i 控制器和 Raid10,备用磁盘自动替换了故障磁盘。操作系统是 RedHat 6。我想进行热插拔工作以在服务器中安装新磁盘。

我的问题是,更换硬盘还需要什么其他操作?就像Solaris中的“# zpool replace c1t2d0 c1t3d0”命令一样。

新磁盘将自动构建还是手动构建?

  #hpacucli ctrl all show config
  Smart Array P420i in Slot 0 (Embedded) 
  array A (SAS, Unused Space: 0  MB)
  logicaldrive 1 (279.4 GB, RAID 1, OK)

  physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
  physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
  physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK, spare)

  array B (SAS, Unused Space: 0  MB)
  logicaldrive 2 (558.7 GB, RAID 1+0, OK)
  physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
  physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK)
  physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)
  physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, Failed)
  physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK, active spare)

谢谢。

巴西雷亚尔

答案1

移除坏磁盘。用新磁盘替换它。

就这些。

您无需采取任何其他行动。


该驱动器甚至会告诉您要移除哪些磁盘以及不要移除哪些磁盘:

看:https://www.youtube.com/watch?v=PYYRAB17f4s