LSI MegaRAID:如何在专用热空间(DHS)和全局热备用(GHS)之间转换?

LSI MegaRAID:如何在专用热空间(DHS)和全局热备用(GHS)之间转换?

要查看驱动器,请使用storcli /c0 show allstorcli /c0/eXXX/sALL show(替换XXX为机箱 ID 或 EID)。 在我的例子中,输出如下所示:

Drive Information :
=================

--------------------------------------------------------------------------------
EID:Slt DID State DG     Size Intf Med SED PI SeSz Model                Sp Type 
--------------------------------------------------------------------------------
252:0    10 Onln   0 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68AX9N0 U  -    
252:1     9 Onln   0 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68AX9N0 U  -    
252:2    11 Onln   0 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68EUZN0 U  -    
252:3     8 Onln   0 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68EUZN0 U  -    
252:4    12 Onln   - 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68EUZN0 U  -    
252:6    14 GHS    - 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68EUZN0 U  -    
252:7    13 GHS    - 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68EUZN0 U  -    
--------------------------------------------------------------------------------

我该如何转换GHSDHS反过来呢?

答案1

storcli只要磁盘被“分配”为热备用,就不会允许您更改其状态。要取消分配驱动器,您需要“删除”它:

storcli /c0/e252/s7 delete hotsparedrive

这将使连接到控制器 0 的磁盘柜 252 上的磁盘 13(在插槽 7 中)可用:

EID:Slt DID State DG     Size Intf Med SED PI SeSz Model                Sp Type 
--------------------------------------------------------------------------------
252:7    13 UGood  - 2.728 TB SATA HDD N   N  512B WDC WD30EFRX-68EUZN0 U  -    

现在状态为“UGood”。这意味着您可以将磁盘添加到现有阵列或将其转换为专用/全局热备用。

要使其成为全局热备,只需添加它而无需任何额外的选项:

storcli /c0/e252/s7 add hotsparedrive

要将其专用于驱动器组,还需指定驱动器组:

storcli /c0/e252/s7 add hotsparedrive dgs=0,1

此命令会将磁盘作为热备用分配给磁盘组 0 和 1。

要扩展现有的 RAID 5 阵列,请使用以下命令:

storcli /c0/v0 start migrate type=raid5 option=add drives=252:7

/v0是要添加磁盘drives的卷。给出要添加的磁盘列表。列表以逗号分隔,每一项都是EID:Slt(机柜 ID 和插槽),即第一列中的值。

相关内容