要查看驱动器,请使用storcli /c0 show all
或storcli /c0/eXXX/sALL show
(替换XXX
为机箱 ID 或 EID)。 在我的例子中,输出如下所示:
Drive Information :
=================
--------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
--------------------------------------------------------------------------------
252:0 10 Onln 0 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68AX9N0 U -
252:1 9 Onln 0 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68AX9N0 U -
252:2 11 Onln 0 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68EUZN0 U -
252:3 8 Onln 0 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68EUZN0 U -
252:4 12 Onln - 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68EUZN0 U -
252:6 14 GHS - 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68EUZN0 U -
252:7 13 GHS - 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68EUZN0 U -
--------------------------------------------------------------------------------
我该如何转换GHS
或DHS
反过来呢?
答案1
storcli
只要磁盘被“分配”为热备用,就不会允许您更改其状态。要取消分配驱动器,您需要“删除”它:
storcli /c0/e252/s7 delete hotsparedrive
这将使连接到控制器 0 的磁盘柜 252 上的磁盘 13(在插槽 7 中)可用:
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
--------------------------------------------------------------------------------
252:7 13 UGood - 2.728 TB SATA HDD N N 512B WDC WD30EFRX-68EUZN0 U -
现在状态为“UGood”。这意味着您可以将磁盘添加到现有阵列或将其转换为专用/全局热备用。
要使其成为全局热备,只需添加它而无需任何额外的选项:
storcli /c0/e252/s7 add hotsparedrive
要将其专用于驱动器组,还需指定驱动器组:
storcli /c0/e252/s7 add hotsparedrive dgs=0,1
此命令会将磁盘作为热备用分配给磁盘组 0 和 1。
要扩展现有的 RAID 5 阵列,请使用以下命令:
storcli /c0/v0 start migrate type=raid5 option=add drives=252:7
/v0
是要添加磁盘drives
的卷。给出要添加的磁盘列表。列表以逗号分隔,每一项都是EID:Slt