我正在尝试使用带有 LSI 9240-8i 的 NETAPP X412 驱动器 (15K rpm 600GB)。问题是驱动器显示为 0 KB 大小,尝试将驱动器设置为良好状态失败,并显示错误消息“操作不允许”。控制器上的其他驱动器正在运行。
知道可能是什么问题吗?
驱动器信息:
Enclosure Device ID: 64
Slot Number: 30
Enclosure position: 0
Device Id: 20
WWN: 5000C5001D.....
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 0 KB [0x0 Sectors]
Non Coerced Size: 0 KB [0x0 Sectors]
Coerced Size: 0 KB [0x0 Sectors]
Logical Sector Size: 512
Physical Sector Size: 512
Firmware state: Unconfigured(bad)
Device Firmware Level: NA03
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5001d9.....
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: NETAPP X412_S15K75.....
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: Unknown
Link Speed: Unknown
Media Type: Hard Disk Device
Drive: Not Supported
Drive Temperature : N/A
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: Unknown
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : No
Storcli 版本:Ver 1.21.06 2016 年 11 月 18 日
控制器固件:2.130.404-4659
答案1
NetApp 驱动器附带其非常特定的固件,因此很有可能它们被锁定只能在 NetApp 设备中使用。