HPE Proliant DL380 Gen 9 24FF 因读取灯闪烁而出现故障。下面的 ILM 文件表明网络端口出现故障(连接到系统端口)。故障排除指南建议切换系统板。
如果我们有第二个具有完全相同统计数据的 Proliant,我们可以进行完整的磁盘组交换吗?这是否意味着系统将像原始服务器一样运行?以下链接似乎表明它应该有效 https://support.hpe.com/hpsc/doc/public/display?docId=mmr_kc-0112214
域名(SSL 证书?)是否存在问题?我们是否必须将其从域中取出并重新加入域?
Critical,98,PCI Bus,1,4/5/2018 1:04 PM,4/5/2018 1:04 PM,1,PCI Bus Error
(Slot 0, Bus 0, Device 1, Function 0)
Critical,99,Unrecoverable System Error,5,4/5/2018 1:04 PM,4/5/2018 1:04
PM,1,Unrecoverable System Error (NMI) has occurred. System Firmware will
log additional details in a separate IML entry if possible
Critical,100,PCI Bus,2,4/5/2018 1:04 PM,4/5/2018 1:04 PM,1,Uncorrectable PCI
Express Error (Embedded device, Bus 0, Device 1, Function 0, Error status
0x00100000)
Critical,101,Operating System,6,4/5/2018 1:04 PM,4/5/2018 1:04 PM,1,User
Remotely Initiated NMI Switch
Critical,102,Unrecoverable System Error,3,4/5/2018 1:06 PM,4/5/2018 1:06
PM,1,An Unrecoverable System Error (NMI) has occurred (System error code
0x00000000, 0xF000E2C3)
Critical,103,Unrecoverable System Error,3,4/5/2018 1:08 PM,Invalid: 0/0/0
12:00 AM,1,An Unrecoverable System Error (NMI) has occurred (System error
code 0x00000000, 0xF000E2C3)
答案1
如果将磁盘保持在相同的位置,则可以在具有类似智能阵列 RAID 控制器的 ProLiant 系统之间移动磁盘。
RAID 配置位于磁盘上,而不是控制器上。
您的 SSL 证书和 Active Directory 不会受到影响。