smartctl 硬盘检查不显示属性

smartctl 硬盘检查不显示属性

今天我在我的 linux 服务器上安装了应用程序 smartmontools,在测试我的硬盘 (raid1) 后,它没有显示属性。在命令之后

smartctl -a /dev/nvme0n1 

我得到了没有硬盘属性的结果:

=== START OF INFORMATION SECTION ===
Model Number:                       SAMSUNG MZQLB960HAJR-00007
Serial Number:                      S437NE0M802932
Firmware Version:                   EDA5202Q
PCI Vendor/Subsystem ID:            0x144d
IEEE OUI Identifier:                0x002538
Total NVM Capacity:                 960,197,124,096 [960 GB]
Unallocated NVM Capacity:           0
Controller ID:                      4
Number of Namespaces:               1
Namespace 1 Size/Capacity:          960,197,124,096 [960 GB]
Namespace 1 Utilization:            194,981,310,464 [194 GB]
Namespace 1 Formatted LBA Size:     512
Local Time is:                      Thu Mar 26 15:08:55 2020 CET
Firmware Updates (0x17):            3 Slots, Slot 1 R/O, no Reset required
Optional Admin Commands (0x000f):   Security Format Frmw_DL NS_Mngmt
Optional NVM Commands (0x001f):     Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Maximum Data Transfer Size:         512 Pages
Warning  Comp. Temp. Threshold:     87 Celsius
Critical Comp. Temp. Threshold:     88 Celsius
Namespace 1 Features (0x02):        NA_Fields

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +    10.60W       -        -    0  0  0  0        0       0

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 +     512       0         0
 1 -    4096       0         0

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02, NSID 0x1)
Critical Warning:                   0x00
Temperature:                        43 Celsius
Available Spare:                    100%
Available Spare Threshold:          10%
Percentage Used:                    0%
Data Units Read:                    11,731,065 [6.00 TB]
Data Units Written:                 5,120,885 [2.62 TB]
Host Read Commands:                 2,507,634,522
Host Write Commands:                57,970,936
Controller Busy Time:               434
Power Cycles:                       47
Power On Hours:                     3,520
Unsafe Shutdowns:                   3
Media and Data Integrity Errors:    0
Error Information Log Entries:      1
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               43 Celsius
Temperature Sensor 2:               47 Celsius
Temperature Sensor 3:               55 Celsius

Error Information (NVMe Log 0x01, max 64 entries)
No Errors Logged

我该怎么办?或者是制造商的原因?

对于任何帮助,我都很感激。

亲切的问候

黑胡子

答案1

所有响应均由制造商决定。他们必须提供某些参数以保持 SMART 合规性,并且他们可能会提供附加功能,据他们了解,SmartCtl 工具开发人员会将这些功能添加到他们的应用程序中。

制造商甚至不必说明他们提供的所有数字范围所采用的尺度。该工具中的部分数据是通过观察数字变化的方式和原因而随着时间的推移而获得的。