我有一台装有多个驱动器的机器。运行storcli /c0 show
会产生以下相关信息等:
TOPOLOGY :
========
----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
----------------------------------------------------------------------------
0 - - - - RAID6 Optl N 90.952 TB dflt N N none N N
0 0 - - - RAID6 Optl N 90.952 TB dflt N N none N N
0 0 0 0:0 2 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 1 0:1 3 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 2 0:2 4 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 3 0:3 5 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 4 0:4 6 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 5 0:5 7 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 6 1:0 26 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 7 1:1 27 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 8 1:2 28 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 9 1:3 29 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 10 1:4 30 DRIVE Onln Y 9.094 TB dflt N N none - N
0 0 11 1:5 31 DRIVE Onln Y 9.094 TB dflt N N none - N
1 - - - - RAID6 Optl N 90.952 TB dflt N N none N N
1 0 - - - RAID6 Optl N 90.952 TB dflt N N none N N
1 0 0 0:6 8 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 1 0:7 9 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 2 0:8 10 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 3 0:9 11 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 4 0:10 12 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 5 0:11 13 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 6 1:6 32 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 7 1:7 33 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 8 1:8 34 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 9 1:9 35 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 10 1:10 36 DRIVE Onln Y 9.094 TB dflt N N none - N
1 0 11 1:11 37 DRIVE Onln Y 9.094 TB dflt N N none - N
2 - - - - RAID5 Optl N 90.952 TB dflt N N none N N
2 0 - - - RAID5 Optl N 90.952 TB dflt N N none N N
2 0 0 0:12 14 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 1 0:14 16 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 2 0:15 17 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 3 0:16 18 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 4 0:17 19 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 5 0:18 20 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 6 0:19 21 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 7 0:20 22 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 8 0:21 23 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 9 0:22 24 DRIVE Onln Y 9.094 TB dflt N N none - N
2 0 10 0:23 25 DRIVE Onln Y 9.094 TB dflt N N none - N
----------------------------------------------------------------------------
(...snip...)
PD LIST :
=======
----------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------
0:0 2 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:1 3 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:2 4 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:3 5 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:4 6 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:5 7 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:6 8 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:7 9 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:8 10 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:9 11 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:10 12 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:11 13 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:12 14 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:13 38 UGood - 9.094 TB SAS HDD N N 512B ST10000NM0096 D -
0:14 16 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:15 17 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:16 18 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:17 19 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:18 20 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:19 21 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:20 22 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:21 23 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:22 24 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
0:23 25 Onln 2 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:0 26 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:1 27 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:2 28 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:3 29 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:4 30 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:5 31 Onln 0 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:6 32 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:7 33 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:8 34 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:9 35 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:10 36 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
1:11 37 Onln 1 9.094 TB SAS HDD N N 512B ST10000NM0096 U -
----------------------------------------------------------------------------
如您所见,c0/e0/d13
被标记为 UGgood(更换驱动器后),并且驱动器组 2 缺少第 11 行。
使用 将此驱动器添加到 RAID 的正确步骤是什么storcli
?我宁愿通过storcli
而不是重新启动来使用(对我而言)更熟悉的 BIOS RAID 工具。
答案1
如果我以前对使用 storcli 的了解还不错,那么这个应该可以解决问题。但是,运行这些命令需要您自己承担风险……毕竟这是您的数组……我建议您接受这里的任何答案,并对照手册页等进行研究,确保您 100% 正确无误
storcli /c0/e0/s13 插入 dg=2 数组=0 行=11
然后执行 storcli /c0/e0/s13 start rebuild