我有一个 LSI 控制器,带有一个由 4 个驱动器 + 1 个备用驱动器组成的 R10 阵列。Storcli 报告:
----------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------
252:0 3 Onln 0 5.457 TB SATA HDD N N 512B WDC WD6002FRYZ-01WD5B1 U -
252:1 5 Onln 0 5.457 TB SATA HDD N N 512B WDC WD6002FRYZ-01WD5B1 U -
252:2 6 Onln 0 5.457 TB SATA HDD N N 512B WDC WD6002FRYZ-01WD5B1 U -
252:3 7 Onln 0 5.457 TB SATA HDD N N 512B WDC WD6002FRYZ-01WD5B1 U -
252:4 4 UGood - 5.457 TB SATA HDD N N 512B WDC WD6002FRYZ-01WD5B1 U -
----------------------------------------------------------------------------------
slt 4 节目详情:
Drive /c0/e252/s4 Policies/Settings :
===================================
Enclosure position = 1
Connected Port Number = 4(path0)
Sequence Number = 3
Commissioned Spare = No
Emergency Spare = No
我想将驱动器 4 设为全局热备用。另一篇帖子建议使用以下命令:
storcli /c0/e252/s4 add hotsparedrive
但这和上面的“已委托备用”和“紧急备用”有什么关系呢?我只想让这个磁盘成为备用磁盘,以防任何驱动器发生故障。
答案1
Emergency Spare
当控制器使用UGood
驱动器或其他不兼容的全局热备用来重建故障阵列时,这是“最后的”备用方法。在某些控制器型号上,这还会激活警报声音。
Commissioned Spare
仅指示磁盘是否处于正常使用状态或紧急热备用状态(即:如果另一个磁盘发生故障,并且该磁盘取代了它)。