MegaRAID LSI SAS-9266-8i 在刷新固件后无可用的 RAID6

MegaRAID LSI SAS-9266-8i 在刷新固件后无可用的 RAID6

亲爱的 serverfault.com 好心人,

我使用 storcli64 将最新的 Mega 固件(可在 broadcom.com 上找到)刷新到我的 MegaRAID LSI SAS-9266-8i RAID 控制器。一切顺利,但是似乎没有可用的 RAID6。不确定哪里出了问题,但我做了以下事情:

代码:

storcli64 /c0 download file=mr2208fw.rom noverchk
storcli64 /c0 set factory defaults
storcli64 /c0 restart

我还搜索了论坛并尝试使用 dos 和 MegaREC 刷新控制器,但没有成功。

以下是“storcli64 /c0 show all”的输出

CLI Version = 007.1017.0000.0000 May 10, 2019
Operating system = Linux 6.6.7-d-allmods
Controller = 0
Status = Success
Description = None


Basics :
======
Controller = 0
Model = LSI MegaRAID SAS 9266-8i
Serial Number = 
Current Controller Date/Time = 03/10/2024, 12:04:56
Current System Date/time = 03/10/2024, 12:04:56
SAS Address = 500605b005283010
PCI Address = 00:04:00:00
Mfg Date = 00/00/00
Rework Date = 00/00/00
Revision No = 


Version :
=======
Firmware Package Build = 23.34.0-0019
Firmware Version = 3.460.114-6464
Bios Version = 5.50.03.0_4.17.08.00_0x06110200
WebBIOS Version = 6.1-76-e_76-Rel
Preboot CLI Version = 05.07-00:#%00011
NVDATA Version = 2.1507.04-0157
Boot Block Version = 2.05.00.00-0010
Bootloader Version = 07.26.26.219
Driver Name = megaraid_sas
Driver Version = 07.725.01.00-rc1


Bus :
===
Vendor Id = 0x1000
Device Id = 0x5B
SubVendor Id = 0x1000
SubDevice Id = 0x9266
Host Interface = PCI-E
Device Interface = SAS-6G
Bus Number = 4
Device Number = 0
Function Number = 0


Pending Images in Flash :
=======================
Image name = No pending images


Status :
======
Controller Status = Needs Attention
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = NA
PD Firmware Download in progress = No
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = Yes
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No


Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate  = Yes
Reconstruction Rate = Yes
Patrol Read Rate = Yes
Alarm Control = Yes
Cluster Support = No
BBU = NA
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = No
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = No
Snapshot Enabled = No
Support PFK = Yes
Support PI = No
Support Ld BBM Info = No
Support Shield State = Yes
Block SSD Write Disk Cache Change = Yes
Support Suspend Resume BG ops = Yes
Support Emergency Spares = Yes
Support Set Link Speed = Yes
Support Boot Time PFK Change = No
Support JBOD = Yes
Disable Online PFK Change = No
Support Perf Tuning = Yes
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = Yes
Extended LD = No
Support Uneven span  = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = No
Support Ext Enclosure = No
Support Sesmonitoring = No
Support SecurityonJBOD = No
Support ForceFlash = No
Support DisableImmediateIO = No
Support LargeIOSupport = No
Support DrvActivityLEDSetting = Yes
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = Yes
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = No
Support IButton less = No
Support AES Encryption Algorithm = No
Support Encrypted MFC = No
Support Snapdump = No
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = No
Support Secure Boot = No
Support Clear Snapdump = No
Support Debug Queue = No
Support Least Latency Mode = Yes
Support OnDemand Snapdump = No


Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = Yes
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Support SSD Wear Gauge = No


Supported VD Operations :
=======================
Read Policy = No
Write Policy = No
IO Policy = No
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = No
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = No
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = No


Advanced Software Option :
========================

-------------------------------------------------
Adv S/W Opt        Time Remaining           Mode 
-------------------------------------------------
MegaRAID FastPath  Unlimited                -    
MegaRAID RAID5     Unlimited                -    
Cache Offload      Unlimited (Unsupported)  -    
-------------------------------------------------

Safe ID =  K6DSL42AFNLL9M7X2VIRL5LUWTXWC25GB62LK4IZ

HwCfg :
=====
ChipRevision =  C1
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Absent
Alarm = On
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 16MB
On Board Memory Size = 0MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Absent
Upgradable CPLD = Absent
Upgradable PSOC = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 0
ROC temperature(Degree Celsius) = 89


Policies :
========

Policies Table :
==============

------------------------------------------------
Policy                          Current Default 
------------------------------------------------
Predictive Fail Poll Interval   300 sec         
Interrupt Throttle Active Count 16              
Interrupt Throttle Completion   50 us           
Rebuild Rate                    30 %    30%     
PR Rate                         30 %    30%     
BGI Rate                        30 %    30%     
Check Consistency Rate          30 %    30%     
Reconstruction Rate             30 %    30%     
Cache Flush Interval            4s              
------------------------------------------------

Flush Time(Default) = 4s
Drive Coercion Mode = 1GB
Auto Rebuild = On
Battery Warning = Off
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = On
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off


Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = Yes
Enable PreBoot CLI = Yes
Enable BIOS = Yes
Max Drives to Spinup at One Time = 2
Maximum number of direct attached drives to spin up in 1 min = 0
Delay Among Spinup Groups (sec) = 12
Allow Boot with Preserved Cache = Off


High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No


Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WT
Read Policy = No Read Ahead
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = None
ZCR Config = Unknown
Max Chained Enclosures = 2
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = Yes
Zero Based Enclosure Enumeration = No
Disable Puncturing = No
EnableLDBBM = No
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving option = Enabled
TTY Log In Flash = Yes
Auto Enhanced Import = No
BreakMirror RAID Support = No
Disable Join Mirror = No
Enable Shield State = Yes
Time taken to detect CME = 60 sec


Capabilities :
============
Supported Drives = SAS, SATA
RAID Level Supported = RAID0, RAID1(2 or more drives), RAID5, RAID00, RAID10(2 or more drives per span), RAID50
Enable JBOD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 16
Max Spans Per VD = 8
Max Arrays = 16
Max VD per array = 16
Max Number of VDs = 16
Max Parallel Commands = 256
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 20
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Enable Snapdump = No
Enable SCSI Unmap = Yes
FDE Drive Mix Support = No
Min Strip Size = 8 KB
Max Strip Size = 64 KB


Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = 03/16/2024, 03:00:00
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 03/09/2024, 03:00:00
Battery learn Reoccurrence = NA
Next Battery Learn = NA
OEMID = AVAGO

Physical Drives = 8

PD LIST :
=======

----------------------------------------------------------------------------
EID:Slt DID State DG     Size Intf Med SED PI SeSz Model            Sp Type 
----------------------------------------------------------------------------
62:0      9 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
62:1     10 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
62:2      8 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     U  -    
62:3     14 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
62:4     11 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
62:5     12 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
62:6     13 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
62:7     15 UGood -  3.637 TB SAS  HDD Y   N  512B ST4000NM0043     D  -    
----------------------------------------------------------------------------

EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=Unsupported|UGShld=UnConfigured shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported

任何帮助将不胜感激。