34865 是 smartctl 的值,CrystalDiskInfo 显示大约 2300 小时。
这是否意味着 SMART 值被操纵了?
C:\Windows\system32>smartctl -a /dev/sda
smartctl 7.0 2018-12-30 r4883 [x86_64-w64-mingw32-win7-sp1] (sf-7.0-1)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Ultrastar 7K3000
Device Model: Hitachi HUA723030ALA641
Serial Number: ******
LU WWN Device Id: 5 000cca 225d66d1d
Firmware Version: MKAOA840
User Capacity: 3 000 592 982 016 bytes [3,00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Apr 23 11:03:46 2019
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (29509) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off supp
ort.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 492) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always -
0
2 Throughput_Performance 0x0005 100 100 054 Pre-fail Offline -
0
3 Spin_Up_Time 0x0007 120 120 024 Pre-fail Always -
643 (Average 639)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always -
362
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always -
0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always -
0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline -
0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always -
2324
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always -
0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always -
362
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always -
408
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always -
408
194 Temperature_Celsius 0x0002 133 133 000 Old_age Always -
45 (Min/Max 15/58)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always -
0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always -
0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline -
0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always -
0
SMART Error Log Version: 1
ATA Error Count: 8 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 8 occurred at disk power-on lifetime: 34865 hours (1452 days + 17 hours)
When the command that caused the error occurred, the device was active or idle
.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 80 00 18 0e 00 Error: UNC 128 sectors at LBA = 0x000e1800 = 923648
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 18 0e 40 00 00:08:49.876 READ DMA EXT
25 00 80 80 17 0e 40 00 00:08:49.875 READ DMA EXT
25 00 80 00 17 0e 40 00 00:08:49.875 READ DMA EXT
25 00 80 80 16 0e 40 00 00:08:49.875 READ DMA EXT
25 00 80 00 16 0e 40 00 00:08:49.874 READ DMA EXT
Error 7 occurred at disk power-on lifetime: 34865 hours (1452 days + 17 hours)
When the command that caused the error occurred, the device was active or idle
.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 5b 25 0e 0e 00 Error: UNC 91 sectors at LBA = 0x000e0e25 = 921125
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 0e 0e 40 00 00:08:46.977 READ DMA EXT
25 00 80 80 0d 0e 40 00 00:08:46.977 READ DMA EXT
25 00 80 00 0d 0e 40 00 00:08:46.976 READ DMA EXT
25 00 80 80 0c 0e 40 00 00:08:46.976 READ DMA EXT
25 00 80 00 0c 0e 40 00 00:08:46.975 READ DMA EXT
Error 6 occurred at disk power-on lifetime: 34865 hours (1452 days + 17 hours)
When the command that caused the error occurred, the device was active or idle
.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 36 4a 04 0e 00 Error: UNC 54 sectors at LBA = 0x000e044a = 918602
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 04 0e 40 00 00:08:44.012 READ DMA EXT
25 00 80 80 03 0e 40 00 00:08:44.012 READ DMA EXT
25 00 80 00 03 0e 40 00 00:08:44.011 READ DMA EXT
25 00 80 80 02 0e 40 00 00:08:44.011 READ DMA EXT
25 00 80 00 02 0e 40 00 00:08:44.011 READ DMA EXT
Error 5 occurred at disk power-on lifetime: 34865 hours (1452 days + 17 hours)
When the command that caused the error occurred, the device was active or idle
.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 10 70 fa 0d 00 Error: UNC 16 sectors at LBA = 0x000dfa70 = 916080
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 00 fa 0d 40 00 00:08:41.006 READ DMA EXT
25 00 80 80 f9 0d 40 00 00:08:41.006 READ DMA EXT
25 00 80 00 f9 0d 40 00 00:08:41.005 READ DMA EXT
25 00 80 80 f8 0d 40 00 00:08:41.005 READ DMA EXT
25 00 80 00 f8 0d 40 00 00:08:41.005 READ DMA EXT
Error 4 occurred at disk power-on lifetime: 34865 hours (1452 days + 17 hours)
When the command that caused the error occurred, the device was active or idle
.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 6b 95 f0 0d 00 Error: UNC 107 sectors at LBA = 0x000df095 = 913557
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
25 00 80 80 f0 0d 40 00 00:08:38.091 READ DMA EXT
25 00 80 00 f0 0d 40 00 00:08:38.091 READ DMA EXT
25 00 80 80 ef 0d 40 00 00:08:38.091 READ DMA EXT
25 00 80 00 ef 0d 40 00 00:08:38.090 READ DMA EXT
25 00 80 80 ee 0d 40 00 00:08:38.090 READ DMA EXT
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA
_of_first_error
# 1 Extended offline Completed without error 00% 2315 -
# 2 Short offline Completed without error 00% 2306 -
# 3 Short offline Completed without error 00% 2300 -
# 4 Short offline Completed without error 00% 14 -
# 5 Short offline Completed: read failure 50% 34866 878
016
# 6 Short offline Completed without error 00% 34690 -
# 7 Short offline Completed without error 00% 33691 -
# 8 Short offline Completed without error 00% 26299 -
# 9 Short offline Completed without error 00% 19849 -
#10 Short offline Completed without error 00% 4 -
1 of 1 failed self-tests are outdated by newer successful extended offline self-
test # 1
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
答案1
Power_On_Hours
在 smartctl 中为 2324,在 CrystalDiskInfo 中为 2325。在我看来还不错。
9 Power_On_Hours 0x0012 100 100 000 Old_age Always -
2324
值 34865 指的是多个错误,例如LifeTime(hours)
自检日志中的列:
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA
_of_first_error
# 1 Extended offline Completed without error 00% 2315 -
# 2 Short offline Completed without error 00% 2306 -
# 3 Short offline Completed without error 00% 2300 -
# 4 Short offline Completed without error 00% 14 -
# 5 Short offline Completed: read failure 50% 34866 878
016
# 6 Short offline Completed without error 00% 34690 -
# 7 Short offline Completed without error 00% 33691 -
# 8 Short offline Completed without error 00% 26299 -
# 9 Short offline Completed without error 00% 19849 -
#10 Short offline Completed without error 00% 4 -
1 of 1 failed self-tests are outdated by newer successful extended offline self-
test # 1