Solaris 系统中出现系统级错误

Solaris 系统中出现系统级错误

我收到以下错误,这意味着什么?

Oct 19 01:02:25 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016841e00513,0 (sd6):
Oct 19 01:02:25 amra02  drive offline
Oct 19 01:02:25 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016841e00513,0 (sd6):
Oct 19 01:02:25 amra02  drive offline
Oct 19 01:02:25 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016841e00513,0 (sd6):
Oct 19 01:02:25 amra02  drive offline
Oct 19 01:03:07 amra02 scsi: [ID 107833 kern.warning] WARNING: /pci@7c,0/pci10de,377@f/pci1077,142@0/fp@0,0/disk@w5006016041e00513,0 (sd5):

Oct 17 19:53:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 19:53:19 amra02  Command failed to complete...Device is gone
Oct 17 19:53:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 19:53:19 amra02  Command failed to complete...Device is gone
Oct 17 19:53:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 19:53:19 amra02  Command failed to complete...Device is gone
Oct 17 20:03:19 amra02 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/disk@g6006016060702d0051a04cd7773de411 (sd23):
Oct 17 20:03:19 amra02  Command failed to complete...Device is gone

答案1

您失去了连接(即对磁盘的访问)

 5006016841e00513 

id 一个 clarion 控制器,以及

 6006016060702d0051a04cd7773de411

是 SAN 上的 LUN(或磁盘)。

  • 供应商 Clariion
  • 分机号 060702d0051a04cd7773de411
  • CI:LDEV (16) e4:11 (10) 228 - 17

您应该检查您的硬件,或者如果硬件正常,请检查 SAN 交换机上的分区配置。

相关内容