我在 OVH 托管的 FreeNas 服务器上有一个驱动器出现故障。我需要更换驱动器,但我非常清楚他们拉错了驱动器。
FreeNas 未在其 GUI 中报告任何序列号。到目前为止,我已经完成了以下操作,但我不知道如何获取驱动器序列号,或者更好地让 LED 闪烁?
pool: vol0
state: DEGRADED
status: One or more devices could not be opened. Sufficient replicas exist for
the pool to continue functioning in a degraded state.
action: Attach the missing device and online it using 'zpool online'.
see: http://illumos.org/msg/ZFS-8000-2Q
scan: scrub repaired 0 in 15h23m with 0 errors on Sun Jul 9 23:23:55 2017
config:
NAME STATE READ WRITE CKSUM
vol0 DEGRADED 0 0 0
mirror-0 DEGRADED 0 0 0
4720622759705179538 UNAVAIL 0 64 0 was /dev/gptid/2a4bad04-4573-11e7-bd76-001e67cb3c7a
gptid/2af09f67-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
mirror-1 ONLINE 0 0 0
gptid/2b9ad3ca-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
gptid/2c440267-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
mirror-2 ONLINE 0 0 0
gptid/2ce91024-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
gptid/2d8f9a88-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
mirror-3 ONLINE 0 0 0
gptid/2e376cc0-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
gptid/2edb2c23-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
mirror-4 ONLINE 0 0 0
gptid/2f8402f6-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
gptid/302bfda0-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
mirror-5 ONLINE 0 0 0
gptid/30d274f0-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
gptid/317ad2a6-4573-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
logs
gptid/cd56ac86-4576-11e7-bd76-001e67cb3c7a ONLINE 0 0 0
使用 glabel 获取设备:
#glabel status | grep 2af09f67-4573-11e7-bd76-001e67cb3c7a
gptid/2af09f67-4573-11e7-bd76-001e67cb3c7a N/A mfisyspd5p2
下一步是什么?
更新:
进一步阅读表明,如果驱动器未连接到 raid 控制器(所有驱动器都处于直通模式),则此问题将很简单,因为 smartctl 将提供所需的信息。使用 mfiutil:
#mfiutil show drives
mfi0 Physical Drives:
9 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ48KYH> SCSI-6 E1:S5
10 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ49TKH> SCSI-6 E1:S2
11 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ48EMH> SCSI-6 E1:S6
12 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ4AS6H> SCSI-6 E1:S8
13 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ49HWH> SCSI-6 E1:S9
14 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ48RDH> SCSI-6 E1:S10
15 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ48NVH> SCSI-6 E1:S1
16 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ49T1H> SCSI-6 E1:S11
17 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ48T9H> SCSI-6 E1:S4
18 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ4BAMH> SCSI-6 E1:S7
19 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ4A0JH> SCSI-6 E1:S3
20 ( 5589G) JBOD <HGST HUS726060ALS640 A2D0 serial=1EJ4AX8H> SCSI-6 E1:S0
21 ( 149G) JBOD <INTEL SSDSC2BB16 0370 serial=BTWL340106TD160MGN> SATA E2:S4
我现在有序列号和设备,如何将两者映射在一起?
答案1
如果你有一个 LSI MegaRaid(或类似产品),如果它使用微滤驱动程序。使用mfiutil
:
mfiuti show drives
mfiutil locate drive on
如果可能的话应该点亮相应的驱动器。
答案2
最后我找不到将 mfiutil 映射到设备的方法。我确信有办法,但我忘了。最后我重新启动进入 raid 控制器 bios,幸运的是,由于驱动器完全坏了,它显示在控制器中。
我想如果我研究过 megacli 我就可以不用重新启动就实现这一点,这样会更好。
但最终mfisyspd5实际上映射到E1:S9,序列号1EJ49HWH
但总的来说,如果您想运行 ZFS,即使在直通中也不要使用 RAID 控制器,只需获取 HBA。从长远来看,这将为您省去麻烦。