Storcli64 未重建替换磁盘

Storcli64 未重建替换磁盘

我们的基于 LSI 的 RAID 中的一个驱动器发生故障(Avago 3108 MegaRaid)。我们取出该驱动器并用类似的磁盘(容量/速度)替换它。自动重建已启用,但磁盘(128:7)的状态显示其状态为 JBOD 而不是 Onln,因此看起来自动重建不起作用:

----------------------------------------------------------------------------
EID:Slt DID State DG     Size Intf Med SED PI SeSz Model            Sp Type 
----------------------------------------------------------------------------
128:0   140 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:1   137 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:2   151 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:3   144 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:4   171 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:5   138 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:6   147 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:7   172 JBOD   - 9.094 TB SAS  HDD N   N  512B ST10000NM0096    U  -    
128:8   132 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:9   148 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:10  158 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:11  136 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:12  141 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:13  160 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:14  154 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:15  155 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:16  150 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:17  134 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:18  157 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:19  139 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:20  133 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:21  146 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:22  149 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
128:23  159 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:0   166 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:1   170 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:2   167 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:3   169 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:4   168 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:5   156 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:6   135 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:7   142 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:8   161 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:9   145 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:10  143 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
129:11  131 Onln   0 9.094 TB SAS  HDD N   N  4 KB ST10000NM0206    U  -    
----------------------------------------------------------------------------

上次我们更换驱动器时,它确实被重建并添加到阵列中。我仔细检查了自动重建的状态并确认它已打开。

------------------
Ctrl_Prop   Value 
------------------
AutoRebuild ON    
------------------

storcli64 的事件日志显示删除/替换事件,但没有显示任何不兼容配置的问题,例如:

Event Description: PD 98(e0x80/s7)
Event Description: PD 98(e0x80/s7) Path 5000c500868172c9  reset (Type 03)
Event Description: Removed: PD 98(e0x80/s7) Info: enclPd=80, scsiType=0, portMap=00, sasAddr=5000c500868172c9,0000000000000000
Event Description: State change on PD 98(e0x80/s7) from FAILED(11) to UNCONFIGURED_BAD(1)
Event Description: Inserted: PD ac(e0x80/s7)
Event Description: Inserted: PD ac(e0x80/s7) Info: enclPd=80, scsiType=0, portMap=00, sasAddr=5000c500a6f54715,0000000000000000
Event Description: PD ac(e0x80/s7) Inquiry info: Info- SEAG ST10000NM0096    00C9088122 9 TB

我想知道磁盘本身的规格是否会阻止将其添加到 DG。替换驱动器的 SeSz 值不同(512B 与 4K),但速度、容量和连接性(SAS)相同。

答案1

基于此常问问题您不能在一个 DG 中混合使用 512 和 4k 磁盘。对我来说,这就是您将此磁盘作为 JBOD 的原因。

您还可以检查这里来自其他参考资料的关于上述内容的解释。

相关内容