我有一个 Phenom X3-8450e,共有 3 个核心。但是当我在终端上运行“传感器”时,我得到了这个:
$ sensors
atk0110-acpi-0
Adapter: ACPI interface
Vcore Voltage: +0.99 V (min = +0.85 V, max = +1.60 V)
+3.3 Voltage: +3.38 V (min = +2.97 V, max = +3.63 V)
+5 Voltage: +5.02 V (min = +4.50 V, max = +5.50 V)
+12 Voltage: +11.98 V (min = +10.20 V, max = +13.80 V)
CPU FAN Speed: 1985 RPM (min = 600 RPM, max = 7200 RPM)
CHASSIS FAN Speed: 0 RPM (min = 600 RPM, max = 7200 RPM)
POWER FAN Speed: 0 RPM (min = 600 RPM, max = 7200 RPM)
CPU Temperature: +32.0°C (high = +60.0°C, crit = +95.0°C)
MB Temperature: +27.0°C (high = +45.0°C, crit = +95.0°C)
如您所见,它仅显示组合的CPU Temperature: +32.0°C
.
但如何显示每个核心的单独温度呢?
答案1
用于sensors-detect
配置缺少的传感器(如果可用)。
在我的机器上,有第二个传感器设备处理每个核心的传感器:
[...]
coretemp-isa-0000
Adapter: ISA adapter
Physical id 0: +54.0°C (high = +80.0°C, crit = +98.0°C)
Core 0: +53.0°C (high = +80.0°C, crit = +98.0°C)
Core 1: +53.0°C (high = +80.0°C, crit = +98.0°C)
Core 2: +49.0°C (high = +80.0°C, crit = +98.0°C)
Core 3: +54.0°C (high = +80.0°C, crit = +98.0°C)
答案2
您还可以使用 GUI 应用程序X传感器。它会向您显示多个选项卡。其中之一将是ATK0110正如您发布的输出中所示。其他选项卡之一应显示核心温度(可能具有名称核心温度)。