突然断电后恢复硬盘

突然断电后恢复硬盘

以下是我的分区表,

mercurial@providence:~$ sudo fdisk -l
Disk /dev/sda: 465.78 GiB, 500107862016 bytes, 976773168 sectors
Disk model: ST9500420AS     
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 512 bytes / 512 bytes
Disklabel type: dos
Disk identifier: 0xc8000000

Device     Boot     Start       End   Sectors   Size Id Type
/dev/sda1  *         2048    206847    204800   100M  7 HPFS/NTFS/exFAT
/dev/sda2          206848 170128349 169921502    81G  7 HPFS/NTFS/exFAT
/dev/sda3       170144408 337927335 167782928    80G  7 HPFS/NTFS/exFAT
/dev/sda4       337930238 976769023 638838786 304.6G  f W95 Ext'd (LBA)
/dev/sda5       337930240 727652351 389722112 185.9G 83 Linux
/dev/sda6       727654400 968382463 240728064 114.8G 83 Linux
/dev/sda7       968384512 976769023   8384512     4G 82 Linux swap / Solaris

我安装了两个 Linux 发行版,一个在/dev/sda5 ,另一个(Debian)在/dev/sda6

当我启动Debian/dev/sda6断电了。当我重新启动并尝试启动 Debian 时,它无法启动。并显示一些错误。

后来我尝试在其他 Linux 中启动,/dev/sda5系统启动正常,但一直出现此错误。

mercurial@providence:~$ sudo dmesg | grep ata
...
[   40.300376] print_req_error: I/O error, dev sda, sector 727654456 flags 0
[   40.302000] Buffer I/O error on dev sda6, logical block 7, async page read
[   40.303663] ata1: EH complete
[   40.740148] Adding 4192252k swap on /dev/sda7.  Priority:-2 extents:1 across:4192252k FS
[   44.577187] ata1.00: exception Emask 0x0 SAct 0x678000 SErr 0x0 action 0x0
[   44.579899] ata1.00: irq_stat 0x40000008
[   44.582976] ata1.00: failed command: READ FPDMA QUEUED
[   44.585847] ata1.00: cmd 60/00:a8:00:20:5f/01:00:2b:00:00/40 tag 21 ncq dma 131072 in
                        res 41/40:00:38:20:5f/00:01:2b:00:00/00 Emask 0x409 (media error) <F>
[   44.591895] ata1.00: status: { DRDY ERR }
[   44.594937] ata1.00: error: { UNC }
[   44.655930] ata1.00: configured for UDMA/133
[   44.655977] sd 0:0:0:0: [sda] tag#21 FAILED Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE
[   44.655982] sd 0:0:0:0: [sda] tag#21 Sense Key : Medium Error [current] 
[   44.655985] sd 0:0:0:0: [sda] tag#21 Add. Sense: Unrecovered read error - auto reallocate failed
[   44.655990] sd 0:0:0:0: [sda] tag#21 CDB: Read(10) 28 00 2b 5f 20 00 00 01 00 00
[   44.655993] print_req_error: I/O error, dev sda, sector 727654456 flags 0
...

我的硬盘比较健康。

mercurial@providence:~$ sudo  smartctl -a /dev/sda
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-5.2.0-kali2-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Momentus 7200.4
Device Model:     ST9500420AS
Serial Number:    5VJ954YE
LU WWN Device Id: 5 000c50 02eacc16b
Firmware Version: D005SDM1
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Wed Oct  9 11:05:53 2019 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                    was completed without error.
                    Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                    without error or no self-test has ever 
                    been run.
Total time to complete Offline 
data collection:        (    0) seconds.
Offline data collection
capabilities:            (0x7b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    General Purpose Logging supported.
Short self-test routine 
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    ( 106) minutes.
Conveyance self-test routine
recommended polling time:    (   3) minutes.
SCT capabilities:          (0x103f) SCT Status supported.
                    SCT Error Recovery Control supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   097   089   006    Pre-fail  Always       -       176927878
  3 Spin_Up_Time            0x0003   100   098   085    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   094   094   020    Old_age   Always       -       6416
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   078   060   030    Pre-fail  Always       -       78548952961
  9 Power_On_Hours          0x0032   064   064   000    Old_age   Always       -       31923
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   094   037   020    Old_age   Always       -       6304
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       1256
188 Command_Timeout         0x0032   099   095   000    Old_age   Always       -       4295037805
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   060   036   045    Old_age   Always   In_the_past 40 (157 57 40 32 0)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       1140
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       1094
193 Load_Cycle_Count        0x0032   001   001   000    Old_age   Always       -       245233
194 Temperature_Celsius     0x0022   040   064   000    Old_age   Always       -       40 (0 15 0 0 0)
195 Hardware_ECC_Recovered  0x001a   044   024   000    Old_age   Always       -       176927878
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       1
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       1
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       1
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       31560 (96 61 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       144327995
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       25265341
254 Free_Fall_Sensor        0x0032   001   001   000    Old_age   Always       -       88

SMART Error Log Version: 1
ATA Error Count: 978 (device log contains only the most recent five errors)
    CR = Command Register [HEX]
    FR = Features Register [HEX]
    SC = Sector Count Register [HEX]
    SN = Sector Number Register [HEX]
    CL = Cylinder Low Register [HEX]
    CH = Cylinder High Register [HEX]
    DH = Device/Head Register [HEX]
    DC = Device Command Register [HEX]
    ER = Error register [HEX]
    ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 978 occurred at disk power-on lifetime: 31923 hours (1330 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 ff ff ff 4f 00      00:06:53.760  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:53.759  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:53.759  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:53.758  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:53.758  READ FPDMA QUEUED

Error 977 occurred at disk power-on lifetime: 31923 hours (1330 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 ff ff ff 4f 00      00:06:51.007  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:51.007  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:51.007  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:51.006  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:51.006  READ FPDMA QUEUED

Error 976 occurred at disk power-on lifetime: 31923 hours (1330 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 ff ff ff 4f 00      00:06:48.218  READ FPDMA QUEUED
  61 00 38 ff ff ff 4f 00      00:06:48.217  WRITE FPDMA QUEUED
  27 00 00 00 00 00 e0 00      00:06:48.217  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 a0 00      00:06:48.215  IDENTIFY DEVICE
  ef 03 46 00 00 00 a0 00      00:06:48.215  SET FEATURES [Set transfer mode]

Error 975 occurred at disk power-on lifetime: 31923 hours (1330 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 08 ff ff ff 4f 00      00:06:45.262  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:45.256  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:45.246  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:45.242  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:06:45.235  READ FPDMA QUEUED

Error 974 occurred at disk power-on lifetime: 31923 hours (1330 days + 3 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 20 ff ff ff 4f 00      00:01:35.260  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:01:35.253  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:01:35.249  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00      00:01:35.249  READ FPDMA QUEUED
  60 00 18 ff ff ff 4f 00      00:01:35.247  READ FPDMA QUEUED

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     11388         -
# 2  Short offline       Completed without error       00%     10594         -
# 3  Short offline       Completed without error       00%      9649         -
# 4  Short offline       Completed without error       00%      9203         -
# 5  Short offline       Completed without error       00%      8696         -
# 6  Short offline       Completed without error       00%      7998         -
# 7  Short offline       Completed without error       00%      7611         -
# 8  Short offline       Completed without error       00%      7116         -
# 9  Short offline       Completed without error       00%      6753         -
#10  Short offline       Aborted by host               40%      6540         -
#11  Extended offline    Completed without error       00%      6512         -
#12  Short offline       Completed without error       00%      6499         -
#13  Short offline       Completed: read failure       90%      6496         577789318
#14  Short offline       Completed without error       00%      6296         -
#15  Short offline       Completed without error       00%      6182         -
#16  Short offline       Aborted by host               90%      5832         -
#17  Short offline       Completed without error       00%      4715         -
#18  Short offline       Completed without error       00%      4704         -
#19  Short offline       Completed without error       00%      4291         -
#20  Short offline       Completed without error       00%      4252         -
#21  Short offline       Completed without error       00%      4008         -
1 of 1 failed self-tests are outdated by newer successful extended offline self-test #11

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

我今天要换新电池了!除此之外我还能做什么?

编辑

我又做了一些测试,结果呈阳性!

mercurial@providence:~$ sudo smartctl -H /dev/sda6
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-5.2.0-kali2-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
Please note the following marginal Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
190 Airflow_Temperature_Cel 0x0022   053   036   045    Old_age   Always   In_the_past 47 (157 57 48 46 0)

mercurial@providence:~$ sudo badblocks -v /dev/sda6 > badsectors.txt
Checking blocks 0 to 120364031
Checking for bad blocks (read-only test): done                                                 
Pass completed, 4 bad blocks found. (4/0/0 errors)

如您所见,发现了 4 个 BadBlocks...

答案1

坏消息 - 你的硬盘是不是相对健康。好吧,与完全坏掉的驱动器相比,它更健康,但它已损坏。Linux 内核消息和 SMART 日志都确认读取磁盘某些区域时出现错误:

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   097   089   006    Pre-fail  Always       -       176927878
  7 Seek_Error_Rate         0x000f   078   060   030    Pre-fail  Always       -       78548952961
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       1256

我建议创建(并验证)立即备份(或其中的几个)所有重要数据(在所有分区上!)在继续使用这台机器之前 - 最好先手动备份最重要的数据,然后再备份不太重要的数据。

在该磁盘上进行更多活动(包括尝试评估损坏程度)可能会造成更大的损坏。

在您确定已经备份了所有您关心的数据后,您可以用它badblocks(8)来评估损坏的程度。

如果磁盘在保修期内,您可能会得到替换件(如果需要,请务必先销毁所有机密数据,例如使用制造商的低级格式化程序)。如果不在保修期内,我建议购买新磁盘。

如果这些都不是选项,您可以尝试使用badblocks -w强制磁盘重新分配损坏的扇区(或使用专家模式fdisk(8)在磁盘未损坏的区域中创建较小的分区),但即使它起作用,磁盘将来也可能会出现更多问题(因此您可能不应该在其上放置任何不可替代的数据)。

请注意,这将破坏数据,您将需要在所有损坏的分区上重新安装操作系统和数据。(这也badblocks -n只会破坏损坏的文件并使系统的其余部分保持原样,但恕我直言,一次性全新重新安装比永久不确定您收到的任何错误是否是由于系统文件损坏或其他原因造成的更好)

答案2

运行SMARTCTL 检查以获取硬盘健康状况,

mercurial@providence:~$ sudo smartctl -H /dev/sda6
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-5.2.0-kali2-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
Please note the following marginal Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
190 Airflow_Temperature_Cel 0x0022   053   036   045    Old_age   Always   In_the_past 47 (157 57 48 46 0)

在故障分区中查找坏扇区,

mercurial@providence:~$ sudo badblocks -v /dev/sda6 > badsectors.txt
Checking blocks 0 to 120364031
Checking for bad blocks (read-only test): done                                                 
Pass completed, 4 bad blocks found. (4/0/0 errors)

这导致了以下坏块列表,badsectors.txt

28
29
30
31

试运行分区表,

sudo mkfs.ext4 -n /dev/sda6

MAGIC即修复丢失的分区,

sudo e2fsck -f -b 32768 -y /dev/sda6

标记刚刚发现的坏块,

mercurial@providence:~$ sudo e2fsck -l badsectors.txt /dev/sda6
e2fsck 1.45.4 (23-Sep-2019)
Debian: Updating bad block inode.
Pass 1: Checking inodes, blocks, and sizes
Programming error?  block #28 claimed for no reason in process_bad_block.
Programming error?  block #29 claimed for no reason in process_bad_block.
Programming error?  block #30 claimed for no reason in process_bad_block.
Programming error?  block #31 claimed for no reason in process_bad_block.
Pass 2: Checking directory structure
Pass 3: Checking directory connectivity
Pass 4: Checking reference counts
Pass 5: Checking group summary information
Free blocks count wrong for group #0 (22671, counted=22675).
Fix<y>? yes
Free blocks count wrong (18013090, counted=18013094).
Fix<y>? yes

Debian: ***** FILE SYSTEM WAS MODIFIED *****
Debian: 912529/7528448 files (0.6% non-contiguous), 12077914/30091008 blocks

瞧!您已成功恢复包含数据的分区!